Experiment was carded out to simulate different loading level elements under coupling of stray current and 5% chlorine salt solution.When calculating corrosion of reinforcement,the influence of loading should be considered based on the first law of Faraday electrolysis.The current density of the corrosion was measured by the linear polarization resistance method.The function of corrosion current density was obtained by nonlinear fitting method,and the influence coefficient of loading level to electrochemical equivalent was obtained base on the function of corrosion current density.The experimental results show that the corrosion current density increases with stress ratio of concrete structures.The reinforcement corrosion weight can be calculated through the influence coefficients of electrochemical equivalent and the result is in line with the actual situation.
参考文献
[1] | Shucai YANG,Xu YANG.Evaluation of stray current corrosion resistance of concrete in metro construction[J].中国高等学校学术文摘·建筑与土木工程,2008(03):246-252. |
[2] | F.C. Robles Hernandez;G. Plascencia;Kevin Koch .Rail base corrosion problem for North American transit systems[J].Engineering failure analysis,2009(1):281-294. |
[3] | Wei Sun;Ru Mu;Xin Luo .Effect of chloride salt, freeze-thaw cycling and externally applied load on the performance of the concrete[J].Cement and Concrete Research,2002(12):1859-1864. |
[4] | 曹晓斌,吴广宁,付龙海,李增,任晓娜.地铁杂散电流的危害及其防治[J].电气化铁道,2006(04):32-34. |
- 下载量()
- 访问量()
- 您的评分:
-
10%
-
20%
-
30%
-
40%
-
50%