欢迎登录材料期刊网

材料期刊网

高级检索

A carbon paste electrode with added multiwall carbon nanotubes chemically modified with N-(3,4-dihydroxyphenethyl)-3,5-dinitrobenzamide was used as the electrochemical sensor for the determination of trace amounts of isoprenaline. The modified electrode showed good electrocatalytic activity for the anodic oxidation of isoprenaline, which was due to a substantial decrease in the anodic overpo-tential. Under the optimum conditions, measurements using square wave voltammetry had a linear range in the range of 0.3 to 125.0μmol/L of isoprenaline and a detection limit of 0.1μmol/L. The diffusion coefficient and kinetic parameters were determined using electrochemical methods. The relative standard deviation for seven successive assays of 1.0 and 20.0μmol/L isoprenaline were 1.9% and 2.4%, respectively. This electrochemical sensor was successfully applied for the determination of isoprenaline in human urine and injection solution samples.

参考文献

[1] Stryer L.Biochemistry[M].New York:Freeman,1988
[2] Voet D;Voet J G.Biochemistry[M].New York:wiley,1995:1268.
[3] Lupetti K O;Vieira I C;Fatibello-Filho O .[J].Talanta,2001,57:135.
[4] Solich P;Polydorou CK;Koupparis MA;Efstathiou CE .Automated flow-injection spectrophotometric determination of catecholamines (epinephrine and isoproterenol) in pharmaceutical formulations based on ferrous complex formation.[J].Journal of Pharmaceutical and Biomedical Analysis: An International Journal on All Drug-Related Topics in Pharmaceutical, Biomedical and Clinical Analysis,2000(5):781-789.
[5] Nevado JJB.;Laguna PB.;Gallego JML. .SPECTROPHOTOMETRIC DETERMINATION OF CATECHOLAMINES WITH METAPERIODATE BY FLOW-INJECTION ANALYSIS[J].Analytica chimica acta,1995(1/3):293-297.
[6] Jeon H K;Nohta H;Nagaoka H;Ohkura Y .[J].Analytical Sciences,1991,7:257.
[7] Nohta H;Yukizawa T;Ohkura Y;Yoshimura M;Ishida J;Yamaguchi M;;; .Aromatic glycinonitriles and methylamines as pre-column fluorescence derivatization reagents for catecholamines[J].Analytica chimica acta,1997(3):233-240.
[8] Alberts G;Lameris T;van den Meiracker A H;Veld A J M I Boomsma F .[J].Journal of Chromatography B:Biomedical Applications,1999,730:213.
[9] Villanueva Camanas R M;Sanchis Mallols J M;Torres Lapasio J R;Ramis-Ramos V .[J].Analyst,1995,120:1767.
[10] El-Obeid H A .[J].Analytical Letters,1984,17:771.
[11] Watson J R;Lawrence R C .[J].Journal of Pharmaceutical Sciences,1977,66:560.
[12] Yamaguchi M.;Yoshimura M.;Ishida J. .Simultaneous determination of urinary catecholamines and 5-hydroxyindoleamines by high-performance liquid chromatography with fluorescence detection[J].The Analyst: The Analytical Journal of the Royal Society of Chemistry: A Monthly International Publication Dealing with All Branches of Analytical Chemistry,1998(2):307-311.
[13] Qu Y;Moons L;Vandesande F .[J].Journal of Chromatography and Biomedical Applications,1997,704:351.
[14] Mashige F;Matsushima Y;Miyata C;Yamada R Kanazawa H Sakuma I Takai N Shinozuka N Ohkubo A Nakahara K .[J].Biomed Chromatogr BMC,1995,9:221.
[15] Elrod Jr L;Schmit J L;Morley J A .[J].Journal of Chromatography A,1996,723:235.
[16] Zhou G J;Zhang G F;Chem H Y .[J].Analytica Chimica Acta,2002,463:257.
[17] Zhang C;Huang J;Zhang Z;Aizawa M .[J].Analytica Chimica Acta,1998,374:105.
[18] Al Warthan A A;Al-Tamrah S A;Al-Akel A A .[J].Analytical Sciences,1994,10:449.
[19] Ensafi, A.A.;Dadkhah, M.;Karimi-Maleh, H. .Determination of isoproterenol and uric acid by voltammetric method using carbon nanotubes paste electrode and p-chloranil[J].Colloids and Surfaces, B. Biointerfaces,2011(1):148-154.
[20] Ensafi AA;Karimi Maleh H .Voltammetric determination of isoproterenol using multiwall carbon nanotubes-ionic liquid paste electrode.[J].Drug testing and analysis,2011(5):325-330.
[21] Ensafi A A;Khoddami E;Karimi-Maleh H .[J].International Journal of Electrochemical Science,2011,6:2596.
[22] Ahmed MU;Hossain MM;Tamiya E .Electrochemical biosensors for medical and food applications[J].Electroanalysis,2008(6):616-626.
[23] De Marco R;Clarke G;Pejcic B .Ion-selective electrode potentiometry in environmental analysis[J].Electroanalysis,2007(19/20):1987-2001.
[24] Santana M H P;Silva L M D;Freitas A C;Boodts J F C Fernandes K C De Faria L A .[J].Journal of Hazardous Materials,2009,164:10.
[25] Pihel K;Schroeder T J;Mark Wightman R .[J].Analytical Chemistry,1994,66:4532.
[26] Shahrokhian S;Amiri M .[J].Microchimica Acta,2007,157:149.
[27] Beitollahi H;Karimi-Maleh H;Khabazzadeh H .[J].Analytical Chemistry,2008,80:9848.
[28] Ensafi, AA;Karimi-Maleh, H .Modified multiwall carbon nanotubes paste electrode as a sensor for simultaneous determination of 6-thioguanine and folic acid using ferrocenedicarboxylic acid as a mediator[J].Journal of Electroanalytical Chemistry: An International Journal Devoted to All Aspects of Electrode Kinetics, Interfacial Structure, Properties of Electrolytes, Colloid and Biological Electrochemistry,2010(1/2):75-83.
[29] El-Mhammedi M A;Achak M;Hbid M;Bakasse M Hbid T Chtaini A .[J].Journal of Hazardous Materials,2009,170:590.
[30] Sun, W;Li, XQ;Wang, Y;Li, X;Zhao, CZ;Jiao, K .Electrochemistry of myoglobin in Nafion and multi-walled carbon nanotubes modified carbon ionic liquid electrode[J].Bioelectrochemistry,2009(2):170-175.
[31] Jin G P;Chen Q Z;Ding Y F;He J B .[J].Electrochimica Acta,2007,52:2535.
[32] El-Mhammedi M A;Bakasse M;Chtaini A .[J].Journal of Hazardous Materials,2007,145:1.
[33] Sun YX;Wang SF;Zhang XH;Huang YF .Simultaneous determination of epinephrine and ascorbic acid at the electrochemical sensor of triazole SAM modified gold electrode[J].Sensors and Actuators, B. Chemical,2006(1):156-161.
[34] Lev O;Wu Z;Bharathi S;Glezer V Modestov A Gun J Rabinovich L Sampath S .[J].Chemistry of Materials,1997,9:2354.
[35] Ensafi, A.A.;Karimi-Maleh, H.;Mallakpour, S.;Hatami, M. .Simultaneous determination of N-acetylcysteine and acetaminophen by voltammetric method using N-(3,4-dihydroxyphenethyl)-3,5-dinitrobenzamide modified multiwall carbon nanotubes paste electrode[J].Sensors and Actuators, B. Chemical,2011(2):464-472.
[36] Ensafi A A;Karimi-Maleh H.Drug Test Analysis[M].,2011
[37] Ensafi A A;Karimi-Maleh H;Mallakpour S .[J].Electroanalysis,2011,23:147810.
[38] Ensafi A A;Dadkhah-Tehrani S;Karimi-Maleh H .[J].Analytical Sciences,2011,27:409.
[39] Karimi-Maleh, H;Ensafi, AA;Allafchian, AR .Fast and sensitive determination of captopril by voltammetric method using ferrocenedicarboxylic acid modified carbon paste electrode[J].Journal of solid state electrochemistry,2010(1):9-15.
[40] Ensafi A A;Karimi-Maleh H .[J].International Journal of Electrochemical Science,2010,5:1484.
[41] Ensafi, A.A.;Karimi-Maleh, H. .A Voltammetric Sensor Based on Modified Multiwall Carbon Nanotubes for Cysteamine Determination in the Presence of Tryptophan Using p-Aminophenol as a Mediator[J].Electroanalysis,2010(21):2558-2568.
[42] Mirmomtaz E;Ensafi AA;Karimi-Maleh H .Electrocatalytic determination of 6-tioguanine at a p-aminophenol modified carbon paste electrode[J].Electroanalysis,2008(18):1973-1979.
[43] Ensafi, A.A.;Karimi-Maleh, H.;Mallakpour, S. .N-(3,4-Dihydroxyphenethyl)-3,5-dinitrobenzamide-Modified Multiwall Carbon Nanotubes Paste Electrode as a Novel Sensor for Simultaneous Determination of Penicillamine, Uric acid, and Tryptophan[J].Electroanalysis,2011(6):1478-1487.
[44] Bard A J;Faulkner L R.Electrochemical Methods,Funda-mentals and Applications[M].New York:wiley,2001
[45] Galus Z.Fundamentals of Electrochemical Analysis[M].New York:Ellis Horwood,1976
[46] Raoof J B;Ojani R;Karimi-Maleh H .[J].Electroanalysis,2009,20:1259.
[47] Beitollahi, H.;Raoof, J.-B.;Karimi-Maleh, H.;Hosseinzadeh, R. .Electrochemical behavior of isoproterenol in the presence of uric acid and folic acid at a carbon paste electrode modified with 2,7-bis(ferrocenyl ethyl)fluoren-9-one and carbon nanotubes[J].Journal of solid state electrochemistry,2012(4):1701-1707.
上一张 下一张
上一张 下一张
计量
  • 下载量()
  • 访问量()
文章评分
  • 您的评分:
  • 1
    0%
  • 2
    0%
  • 3
    0%
  • 4
    0%
  • 5
    0%