欢迎登录材料期刊网

材料期刊网

高级检索

采用正交法优化封闭溶样前处理条件,石墨炉原子吸收光谱法测定地球化学样品中的痕量金。实验结果表明,前处理最优组合为王水用量30 mL,溶解时间60 min,吸附时间40 min,解脱时间40 min。该方法的检出限为0.16 ng/g。经国家一级标准物质验证,该方法精密度、准确度均适用于地球化学样品中痕量金的测定。

In this paper ,orthogonal design was used for optimizing pretreatment conditions of sealed dissolution . Meanwhile ,trace gold in geochemical samples were determined by graphite furnace atomic absorption spectrometry ( GFAAS) .And the optimized addition of aqua regia , dissolution time , adsorption and desorption time were 30 mL, 60 min,40 min,40 min,respectively.Detection limit of the method was 0.16 ng/g.The precision and accuracy of method have been applicable to the determination of trace gold in geochemical samples by according to the consistent determination in national standard samples .

参考文献

[1] 正交试验设计表的使用分析[J].编辑学报,2005(05):334-335.
[2] 徐仲安,王天保,李常英,暴丽艳,马青梅,苗玉宁.正交试验设计法简介[J].科技情报开发与经济,2002(05):148-150.
[3] 周康民;王璇 .正交试验在实验设计中的应用[J].江苏地质,1998,22(04):213-215.
[4] 杨明荣,孙鹏,牟长贤,石爱萍.金矿样品的几种溶样方法[J].黄金地质,2004(01):68-70.
[5] 薛光,张厚杰.原子吸收法快速测定金精矿中的银[J].黄金,2010(02):57-58.
[6] 赵玉娥,薛光.微波封闭溶样分光光度法测定催化剂中的钯[J].黄金,2008(09):48-49.
[7] 姚万林,薛光,黄洪凌,刘建忠.原子吸收测定含银矿石的预处理方法[J].黄金,2008(02):54-56.
[8] 薛光,梁永清.微波封闭溶样原子吸收法快速测定金精矿中的铅[J].黄金,2008(08):55-56.
[9] 邱宏喜,陈占生,张汝生,张永红.金矿封闭溶样法的优化[J].黄金,2008(11):50-52.
[10] 郭卫国,王玉玲,薛光.微波密闭溶样火焰原子吸收光谱法测定金精矿中银、铜、锌[J].理化检验-化学分册,2008(02):181-182.
[11] 薛光;姚万林 .无污染封闭溶样设备在金、银及其伴生元素分析中的应用[J].黄金,1998,19(12):48-50.
[12] DZ/T 0130-2006.地质矿产实验室测试质量管理规范[S].北京:中国标准出版社,2006.