为了完善元坝气田集输系统防腐蚀监测手段,在现场使用了两套国产场指纹监测系统(iEMMCA-1),两套系统均和进口系统相邻且安装在具有环向焊缝的管道上.对两套国产场指纹系统的监测数据进行分析,并与相邻的超声波探针测得的均匀腐蚀速率进行对比.近8个月的监测结果表明:国产场指纹腐蚀监测系统具有良好的精度和可靠性.
参考文献
[1] | 李俊菀;宋敬霞;曹杰玉;王红卫.某电厂3号机组发电机内冷水系统碱性富氧运行工况评价[J].腐蚀与防护,2014(11):1140-1143. |
[2] | 李占坤;孙彪;王喜乐;王国瑞;宝音.塔河油田油气集输管网腐蚀现状及防腐蚀技术[J].腐蚀与防护,2015(3):240-244,299. |
[3] | 张江江;张志宏.雅克拉气田天然气西气东输管道腐蚀与检测评价[J].腐蚀与防护,2015(3):234-239. |
[4] | Gan, Fangji;Wan, Zhengjun;Li, Yuting;Liao, Junbi;Li, Wenqiang.Improved formula for localized corrosion using field signature method[J].Measurement,2015:137-142. |
[5] | 万正军;廖俊必;王裕康;殷国富.基于电位列阵的金属管道坑蚀监测研究[J].仪器仪表学报,2011(1):19-25. |
[6] | Giuseppe Sposito;Peter Cawley;Peter B. Nagy.Potential drop mapping for the monitoring of corrosion or erosion[J].NDT & E International: Independent Nondestructive Testing and Evaluation,20105(5):394-402. |
[7] | Bowler N.Theory of four-point alternating current potential drop measurements on a metal half-space[J].Journal of Physics, D. Applied Physics: A Europhysics Journal,20063(3):584-589. |