利用硫酸-硫酸铜腐蚀试验方法和双环电化学动电位再活化法(DL-EPR),对304不锈钢薄板在预应变和敏化之后的晶间腐蚀敏感性进行了研究.采用金相显微镜对经过硫酸-硫酸铜试验后的试样进行观察,利用电化学测试方法进行试样敏化度(DOS)的测量.结果表明:304不锈钢薄板经过预应变-敏化处理后的晶间腐蚀程度较经单一敏化处理后的更加严重,随着预应变的加大,晶间腐蚀加重,敏化度也提高.
参考文献
[1] | 邵拥军;逯凯霄;张文林.板式换热器的特点与优化设计[J].广州化工,2012(6):120-122. |
[2] | 晋圣发.400℃时效对304不锈钢晶间敏化行为的影响[J].压力容器,2013(09):24-30. |
[3] | 姜爱华;陈亮;丁毅;马立群.304不锈钢晶间敏化行为[J].腐蚀与防护,2013(5):423-425. |
[4] | Raghuvir Singh.Influence of cold rolling on sensitization and intergranular stress corrosion cracking of AISI 304 aged at 500℃[J].Journal of Materials Processing Technology,20081/3(1/3):286-293. |
[5] | Parag M. Ahmedabadi;Vivekanand Kain;Bhupinder Kumar Dangi;I. Samajdar.Role of grain boundary nature and residual strain in controlling sensitisation of type 304 stainless steel[J].Corrosion Science: The Journal on Environmental Degradation of Materials and its Control,2013Jan.(Jan.):242-255. |
[6] | Surface spreading of intergranular corrosion on stainless steels[J].Corrosion Science: The Journal on Environmental Degradation of Materials and its Control,20103(3):873. |
[7] | 胡长亮;夏爽;李慧;刘廷光;周邦新;陈文觉.晶界网络特征对304不锈钢晶间应力腐蚀开裂的影响[J].金属学报,2011(7):939-945. |