欢迎登录材料期刊网

材料期刊网

高级检索

微波等离子体炬原子发射光谱法(MPT-AES)是利用微波源提供能量,其与电感耦合等离子体原子发射光谱法(ICP-AES)特点类似,具有原子化效率高、分析速度快和操作简单等优点,但是目前对该技术的应用研究仅限于仪器工作条件的优化,对某些共存元素的干扰缺乏有效的解决措施。实验以氩气为载气和工作气,详细考察了MPT-AES测定原油中钙的工作条件和共存元素对钙测定的影响。结果表明,选择Ca 393.366 nm为分析谱线,微波功率为85 W ,载气流量为1350 mL/min ,工作气流量为650 mL/min ,钙质量浓度在0.010~6.00μg/m L范围内与其对应的发射强度呈线性,线性相关系数 r=0.9998;方法中钙的检出限为5.6×10-3μg/mL。干扰试验结果表明,7倍于钙质量浓度的钠,3倍于钙质量浓度的铁、钴,1倍于钙质量浓度的镁、铜、铝不影响钙的测定;1倍于钙质量浓度的钒、镍干扰钙的测定。在0.5 mL 5 g/L EDTA和0.5 mL 10 g/L 邻菲罗啉溶液的联合作用下,可使铝、钴、镍、镁、铁、铜、钒的允许量至少提高到5倍。将实验方法应用于原油中钙的测定,测定结果与火焰原子吸收光谱法(FAAS)基本一致,相对标准偏差(RSD ,n=6)为1.6%~2.2%。

The energy in microwave plasma torch atomic emission spectrometry (MPT-AES) is supplied by microwave ,which is similar to the characteristic of inductively coupled plasma atomic emission spectrome-try (ICP-AES) .It has some advantages such as high atomization efficiency ,rapid analysis speed and sim-ple operation .However ,the application researches of this technology is only limited in the optimization of instrumental working conditions at present ,and lack of effective solving measures for the interference of some coexisting elements .Argon was selected as carrier gas and working gas .The working conditions for the determination of calcium in crude oil by MPT-AES were investigated .Meanwhile ,the influence of co-existing elements on the determination of calcium was discussed .The results showed that the mass concen-tration of calcium in range of 0 .010-6 .00 μg/mL was linear to the corresponding emission intensity with correlation coefficient of r=0 .999 8 under the following experimental conditions :the analytical line was Ca 393 .366 nm ,the microwave power was 85 W ,the carrier gas flow rate was 1 350 mL/min ,and the work-ing gas flow rate was 650 mL/min .The detection limit of calcium was 5 .6 × 10-3 μg/mL .The interference test results indicated that the determination of calcium was not influenced by 7 times (mass concentration) of sodium ,3 times of iron and cobalt ,1 time of magnesium ,copper and aluminum .However ,1 time of vanadium and nickel had interference .The tolerant amount of aluminum ,cobalt ,nickel ,magnesium , iron ,copper and vanadium could be increased by 5 times using 0 .5 mL of 5 g/L EDTA and 0 .5 mL of 10 g/L phenanthroline solution . The experimental method was applied to the determination of calcium in crude oil ,and the found results were basically consistent with those obtained by flame atomic absorption spectrometry (FAAS) .The relative standard deviations (RSD ,n=6) were between 1 .6% and 2 .2% .

参考文献

[1] 张学佳;纪巍;康志军;孙大勇;那荣喜;单伟;王建.原油中钙的危害及脱钙技术[J].石油与天然气化工,2008(4):307-311.
[2] 庞晓辉;高颂;房丽娜.电感耦合等离子体原子发射光谱法测定钎剂中硼钠钙[J].分析仪器,2015(4):46-49.
[3] 刘立行;郑永勇.非完全消化-火焰原子光谱法测定润滑油添加剂中钙、钡、锌[J].冶金分析,2005(4):15-17.
[4] FEI Yan-qun;LUO Gui-min;FENG Guo-dong;CHEN Huan-wen;FEI Qiang;HUAN Yan-fu;JIN Qin-han.Iodine Determination by Microwave Plasma Torch Atomic Emission Spectrometer Coupled with Online Preconcentration Vapor Generation Technique[J].高等学校化学研究(英文版),2008(05):546-549.
[5] 薛丽敏;李丽华;张金生;王庆明.MPT-AES法测定茶叶中的锶[J].广州化工,2010(6):173-174,190.
[6] 李丽华;张金生;张起凯.MPT-AES测定奶粉中的Ca和Fe[J].分析试验室,2005(6):47-49.
[7] 徐春秀;蔡龙飞;萧柽霞.原子发射光谱法分析木瓜中的微量元素[J].食品研究与开发,2014(3):75-77.
[8] 李丽华;张金生;张起凯;杨英;邴乃慈;马毅.MPT-AES测定矿泉水中的Ca、Mg和Na[J].石油化工高等学校学报,2002(2):46-48,67.
[9] 李秀萍;赵荣祥;李丽华;张金生.半灰化-微波消解-MPT-AES测定大豆皮中的金属元素[J].大豆科学,2011(2):314-317.
[10] 卢莹冰;高德忠;李丽华;张金生;陈雨艳.MPT-AES同时测定航空润滑油中的铝、镁和铜[J].光谱实验室,2005(1):95-98.
[11] 张金生;李丽华;金钦汉.微波消解-微波等离子体炬原子发射光谱法测定原油和渣油中的铁、镍、铜和钠[J].分析化学,2005(5):690-694.
[12] 李秀萍;李丽华;张金生.MPT-AES法测定乳胶手套中的铁、镍、镁、钙、锌[J].分析测试学报,2007(5):754-756.
[13] 李丽华;张金生;卢莹冰;宫晓杰.MPT-AES法测定汽油中的铜和铁[J].辽宁石油化工大学学报,2009(4):12-14.
[14] 钱梅;王建荣;艾宏承.火焰原子吸收光谱法测定原油及润滑油馏分中钙含量[J].润滑油,2002(5):52-56.
上一张 下一张
上一张 下一张
计量
  • 下载量()
  • 访问量()
文章评分
  • 您的评分:
  • 1
    0%
  • 2
    0%
  • 3
    0%
  • 4
    0%
  • 5
    0%