采用自制的氩气氛围电感耦合等离子体(ICP)离子源封闭装置,使ICP离子源与空气隔离,形成氩气氛围ICP离子源,研究了溶液雾化进样和激光剥蚀进样情况下电感耦合等离子体质谱(ICP-MS)的分析性能,证实氩气氛围ICP-MS在改善O、N、C、Ar等组成的多原子离子干扰方面具有明显的优势.在溶液进样的情况下,研究了11B、24Mg、28Si、42Ca、53Cr、54Fe、55Mn、60Ni、65Cu、89Y、115 In、137Ba、202Hg、208pb等的线性相关系数、检出限和背景等效浓度,结果表明,对易受N、C、Ar等组成的多原子离子干扰的24Mg、28Si、42Ca、53Cr、54Fe、55Mn、60Ni、65Cu,其分析性能得到明显改善;对11B、89Y、115 In、137Ba、202 Hg、208pb等同位素没有负面影响.在激光剥蚀的情况下,紫铜中31p、54Fe、56Fe、60Ni、66Zn、107Ag、121Sb、208pb、209Bi等的分析性能都有所改善,尤其以54Fe、56Fe的改善更为明显.利用该技术,采用激光剥蚀ICP MS测定了纯铜样品中P、Fe、Ni、Zn、Ag、Sb、Pb和Bi等元素,测定结果与溶液雾化进样ICP MS (SNICP MS)基本吻合,各元素的检出限分别为6、24、3、1、1、1、1和0.01 μg/g.

参考文献

[1] Nonose N S;Matsuda N;Fudagawa N et al.Some characteristics of polyatomic ion spectra in inductively coupled plasma mass spectrometry[J].Spectrochimica Acta Part B,1994,49B(10):955-974.
[2] R.S.Houk;Narong Praphairaksit .Dissociation of polyatomic ions in the inductively coupled plasma[J].Spectrochimica Acta, Part B. Atomic Spectroscopy,2001(7):1069-1096.
[3] Zahran N F;Helal A I;Amr M A et al.Formation of polyatomic ions from the skimmer cone in the inductively coupled plasma mass spectrometry[J].International Journal of Mass Spectrometry,2003,226(02):271-278.
[4] 胡净宇,王海舟.电感耦合等离子体质谱干扰对钢铁及合金痕量分析的影响[J].冶金分析,2007(03):18-24.
[5] 成勇.微波消解-电感耦合等离子体质谱法测定高纯镍板中痕量元素[J].冶金分析,2008(03):9-13.
[6] 杨植岗,沈学静,王蓬,胡少成,马红权,王海舟.氧氮联测技术中CO++对N+质谱干扰校正方法建立及应用[J].冶金分析,2013(03):1-8.
[7] Lam J W H;Horlick G .A comparison of argon and mixed gas plasmas for inductively coupled plasmamass spectrometry[J].Spectrochimica Acta Part B,1990,45:1313-1325.
[8] Smith F G;Wiederin D R;Houk R S .Argon-xenon plasma for alleviating polyatomic ion interferences in inductively coupled plasma mass spectrometry[J].Analytical Chemistry,1991,63:1458-1462.
[9] Sheppard B S;Shen W L;Davidson T M et al.Helium argon inductively coupled plasma for plasma source mass spectrometry[J].Journal of Analytical Atomic Spectrometry,1990,5:697-700.
[10] Laborda F;Baxter M J;Crews H M et al.Reduction of polyatomic interferences in inductively coupled plasma mass spectrometry by selection of instrumental parameters and using an argon-nitrogen plasma:effect on multi element analyses[J].Journal of Analytical Atomic Spectrometry,1994,9:727-736.
[11] Hill S J;Ford M J;Ebdon L .Investigations into the application of methane addition to the nebulizer gas in inductively coupled plasma mass spectrometry for the removal of polyatomic interferences[J].Journal of Analytical Atomic Spectrometry,1992,7:1157-1165.
[12] Van der Velde-Koerts T;De Boer J L M .Minimization of spectral interferences in inductively coupled plasma mass spectrometry by simplex optimization and nitrogen addition to the aerosol carrier for multielement environmental analysis[J].Journal of Analytical Atomic Spectrometry,1994,9:1093-1098.
[13] Evans E H;Ebdon L .Effect of organic solvents and molecular gases on polyatomic ion interferences in inductively coupled plasma mass spectrometry[J].Journal of Analytical Atomic Spectrometry,1990,5:425-430.
[14] Louie H;Soo S Y P .Use of nitrogen and hydrogen in inductively coupled plasma mass spectrometry[J].Journal of Analytical Atomic Spectrometry,1992,7:557-564.
[15] Jin QH.;Liang F.;Zhang HQ.;Yu AM.;Cao YB.;Zhou JG.;Xu B.;Yang WJ. .Recent advances in microwave plasma torch atomic emission spectrometry - Invited lecture[J].Journal of Analytical Atomic Spectrometry,1998(5):377-384.
[16] Brian W. Pack;Gary M. Hieftje .An improved microwave plasma torch for atomic spectrometry[J].Spectrochimica Acta, Part B. Atomic Spectroscopy,1997(14):2163-2168.