为研究钝化剂对含腐蚀性硫变压器油的影响,对14台变压器添加钝化剂后的运行进行监控,监测变压器油中钝化剂的消耗情况、油中腐蚀性硫含量变化、油品理化性能及电气性能变化等.结果表明:添加钝化剂后,随着时间的延长,钝化剂逐渐消耗,月平均消耗量为6 mg/kg;钝化剂添加后,变压器油中的腐蚀性硫DBDS含量基本保持不变,说明腐蚀性硫未与铜导线发生反应,钝化剂能够有效缓解DBDS对铜导线的腐蚀;钝化剂的添加对变压器油的电气性能、物化性能及油中气体含量没有影响.
To research the effect of passivator on the transformer oil with corrosive sulfur, the operating status of 14 transformers after adding passivator were monitored, including the consumption condition of passivator, the variation of corrosive sulfur content in oil and physicochemical and electrical properities of transformer oil. The results show that after adding passivator to the transformer oil, the passivator consumes gradually with the prolonging of time, and the average consumption per month is about 6 mg/kg. The corrosive sulfur DBDS content keeps stable, which indicates that the corrosive sulfur do not react with the copper conductor and the passivator can effectively relieve the corrosion of copper conductor from DBDS. The passivator has no effect on the physical, chemical, and electrical properities of transformer oil and the gas content in oil.
参考文献
[1] | F. Scatiggio;V. Tumiatti;R. Maina;M. Tumiatti;M. Pompili;R. Bartnikas.Corrosive Sulfur in Insulating Oils: Its Detection and Correlated Power Apparatus Failures[J].IEEE Transactions on Power Delivery,20081(1):508-509. |
[2] | 钱艺华;胡红红;姚唯建.腐蚀性硫导致变压器故障的综合分析及处理[J].变压器,2008(1):28-30. |
[3] | 李睿;曹顺安;钱艺华;盛凯.变压器油中腐蚀性硫的研究现状[J].变压器,2009(2):19-22. |
[4] | 任双赞;钟力生;曹晓珑.矿物绝缘油中腐蚀性硫问题研究[J].绝缘材料,2010(3):69-73. |
[5] | 唐峰;刘湘平.主变压器典型故障成因分析及防治措施[J].广东电力,2008(12):77-79. |
[6] | 于会民;马书杰;孟玉婵;张绮;张玲俊;郭春梅.金属减活剂抑制变压器硫腐蚀应用研究[J].变压器,2011(2):36-42. |
[7] | 任双赞;秦司晨;蒲路;黄国强;朱红梅;单玉涛.矿物绝缘油中腐蚀性硫问题的应对措施研究[J].高压电器,2014(9):53-57. |
[8] | 钱艺华;姚唯建;李智.广东电网500 kV变压器绝缘油腐蚀性硫的现状和解决对策[J].变压器,2011(1):44-46. |
[9] | Martins, M.A.G..Experimental study of the thermal stability of irgamet 39 and dibenzyl disulfide in the laboratory and in transformers in service[J].IEEE Electrical Insulation Magazine,20144(4):28-33. |
[10] | 万涛;钱晖;徐松;冯兵.T551金属减活剂对变压器油中铜腐蚀抑制作用研究[J].石油炼制与化工,2012(11):69-72. |
[11] | Martins, M.A.G.;Gomes, A.R.;Pahlavanpour, B..Experimental study of a passivated oil corrosiveness, after depletion of the passivator[J].IEEE Electrical Insulation Magazine,20096(6):23-27. |
[12] | Amimoto, T.;Nagao, E.;Tanimura, J.;Toyama, S.;Yamada, N..Duration and mechanism for suppressive effect of triazole-based passivators on copper-sulfide deposition on insulating paper[J].IEEE transactions on dielectrics and electrical insulation: A publication of the IEEE Dielectrics and Electrical Insulation Society,20091(1):257-264. |
[13] | Wan, T..Suppressive mechanism of the passivator irgamet 39 on the corrosion of copper conductors in transformers[J].IEEE transactions on dielectrics and electrical insulation: A publication of the IEEE Dielectrics and Electrical Insulation Society,20122(2):454-459. |
[14] | Yihua Qian;Wei Su.Research on Influencing Factors of Corrosive Sulfur Attacking Copper in Insulating Oil and Prevention[J].IEEJ Transactions on Electrical and Electronic Engineering,20136(6):546-549. |