提出了一种在金属熔体中使用的新型长寿命氧传感器;利用氧浓差电池的可逆性,在测试间隙对氧电池施加大小适当的补偿电流,可消除或减小参比电极的极化,使普通氧传感器的使用寿命延长10倍以上;推导了补偿电流密度的计算公式,并得到了验证.
参考文献
[1] | Nagata K,Goto K S.Solid State Ionics,1983; 9/10:1249 |
[2] | Worrell W L,Liu Q G.Solid State Ionics,1990; 40/41:761 |
[3] | Tang Y,Li F S,Liu Q G.Iron Steel,1994; 29(10):53(唐育华,李福燊,刘庆国.钢铁,1994;29(10):53) |
[4] | Janke D,Hagen K,Hammerschmid P,Dittert D,Lindenberg H U,Weber L.Stahl Eisen,1987; 107:537 |
[5] | Dimitrov S,Ranganathan S,Weyl A,Janke D.Steel Res,1993; 64(1):63 |
[6] | Ranganathan S,Janke D.Scr Metall Mater,1993; 29(3):305 |
[7] | Li F S,Zhu Z G.Chin Pat ZL 91 1 00437.8,1991(李福燊,朱志刚.中国专利ZL 91 1 00437.8,1991) |
[8] | Wang C Z.Research Methods of Physical Chemistry of Metallurgy.Beijing:Metallurgical Industry Press,1992:171(王常珍.冶金物理化学研究方法北京:冶金工业出版社,1992:171) |
[9] | Zhu Z G.Master Dissertation,University of Science and Technology Beijing,1990(朱志刚.北京科技大学硕士论文,1990) |
[10] | Lu X Q,Li F S,Li L F,Zhou G Z.J Inorg Mater,1997;12(4):531(鲁雄刚,李福燊,李丽芬,周国治.无机材料学报,1997;12(4):531) |
上一张
下一张
上一张
下一张
计量
- 下载量()
- 访问量()
文章评分
- 您的评分:
-
10%
-
20%
-
30%
-
40%
-
50%