欢迎登录材料期刊网

材料期刊网

高级检索

对Sn-3.0Ag-0.5Cu无铅体钎料和Sn-4.0Ag-0.5Cu无铅钎料BGA(ball grid array)焊点进行了Berkovich纳米压痕法实验,通过改变不同的加载速率研究了钎料的蠕变特征.钎料压痕载荷-位移曲线蠕变部分表现出了明显的加载速率相关性.基于Oliver-Pharrr法确定的体钎料和BGA焊点的Young's模量分别为9.3和20 GPa.基于压痕做功概念确定的体钎料和BGA焊点的应变速率敏感指数分别为0.1111和0.0574.钎料的力学性能有着明显的尺寸效应.

参考文献

[1] Manson S S. Thermal Stress and Low-Cycle Fatigue. New York: Mcgraw-Hill, 1966
[2] Villain J, Brueller O S, Qasim T. Sens Actuators, 2002;99A: 194
[3] Wiese S, Feustel F, Meusel E. Sens Actuators, 2002; 99A:188
[4] Wiese S, Schubert A, Walter H, Dudek R, Feustel F,Meusel E, Michel B. In: Proceedings IEEE 51th Electronic Components and Technology Conference, Orlando: IEEE,2001:890
[5] Oliver W C, Pharr G M. J Mater Res, 1992; 7:1564
[6] Suresh S, Giannakopoulos A E. Acta Mater, 1998; 46:5755
[7] Giannakopoulos A E, Suresh S. Scr Mater, 1999; 40:1191
[8] Fujiwara M, Otsuka M. Mater Sci Eng, 2001; A319-321:929
[9] Ma X, Yoshida F. Appl Phys Lett, 2003; 82:188
[10] Zeng K, Tu K N. Mater Sci Eng Rep, 2002; 38:55
[11] JIS Z 3198. Test Methods for Lead-Free Solders, Japanese Industrial Standard, 2003
[12] Stiwell N A, Tabor D. Prog Phys Soc, 1961; 78:169
[13] Johnson K L. J Mech Phys Solids, 1970; 18:115
[14] Pao Y H, Badgley S, Govila R, Jih E. Mater Res Soc Symp Proc, 1994; 323:128