高级检索

用电弧离子镀设备,在医用不锈钢基体上沉积Ti/TiN纳米多层薄膜,考察薄膜在Troyde′s模拟体液中的抗腐蚀性能.结果表明,在中性与酸性模拟体液中316L+Ti/TiN(45/45s)体系的击穿电位分别提高5倍和2倍,腐蚀电流密度为基体的1/8与1/3,明显降低发生局部腐蚀的敏感性,但滞后环的出现说明薄膜被击穿后自修复能力较差.分析说明薄膜的纳米多层结构与纯Ti层的存在可有效提高医用不锈钢在Troyde′s模拟体液中的抗点蚀能力.

参考文献

[1] Overview of Biomaterils and Their Use in Medical Devices. Handbook of Materials for Medical Devices.Chapter 1.
[2] SteinemannS G. Injury, 1996, 27(3): 16-21.
[3] 黄美东,孙超,林国强,等.金属学报,2003,5:516-520.
[4] Jones M I, McColl I R, Grant D M, et al. Jouranal of Biomedical Materials Research, 2000, 52(2): 413-421.
[5] Herranen M, Wiklund U, Carlsson J O, et al. Surface and Coatings Technology, 1998, 99: 191-196.
[6] Hubler R, Cozza A, Marcondes T L, et al. Surface and Coatings Technology, 2002,142-144: 1078-1083.
[7] Prawer S, Nugent K W, Lifshitz Y, et al. Diamond and Related Materials, 1996, 5: 433-437.
[8] 梁成浩,郭亮,隋洪艳.稀有金属材料与工程,2001,30(6):433-436.
[9] Li Ying, Li Qu, Wang Fuihui. Corrosion Science, 2003, 45: 1367-1372.
[10] Lakatos-Varsanyi M, Darko Hanzel. Corrosion Science, 1999, 41: 1585-1590.
[11] Marco J F, Agudelo A C, Gancedo J R, et al. Surf. Interface Anal., 1999, 27: 71-75.
[12] Chen Jia-Yang, Yu Ge-Ping, Huang Jia-hong. Materials Chemistry and Physics, 2000, 65: 310-315.
[13] Wang H W, Stack M M, Lyon S B, et al. Surface and Coating Technology, 2000, 126: 279-287.