采用高效毛细管电泳法测定人尿中姜黄素的含量,建立了一种测定体液中姜黄素的简便的分析方法.所用缓冲溶液为15 mmol/L的硼砂溶液(pH 9.24),运行电压为20 kV,检测波长262 nm.姜黄素的峰面积与其质量浓度的线性关系良好,其线性范围为10~300 mg/L,健康人尿中姜黄素的4个浓度水平的添加回收率均大于96.3% ,相对标准偏差(RSD)小于2.3% .该法灵敏、快速、准确,可用于体液中姜黄素的批量检测.
参考文献
[1] | Soudamini K K, Kuttan R. India J Pharmacol, 1988, 20(2): 95 |
[2] | Elizabeth K, Rao M N A. Int J Pharm, 1990, 58: 240 |
[3] | Li C J, Zhang L J, Dezube B J, Crumpacker C S, Pardee A B. Proc Natl Acad Sci USA, 1993, 90: 1 839 |
[4] | Lampe V, Milobedeska J, Kostanecki V. Ber Dtsch Chem Ges, 1910, 43: 2 163 |
[5] | Jentzsch K, Spiegl P, Kamitz R. Sci Pharm, 1970, 38(1): 50 |
[6] | Janssen A, Gole Th. Chromatographia, 1984, 18(10): 546 |
[7] | Cooray N F. J Natl Sci Counc Sri Lanka, 1988, 16: 39 |
[8] | Sanagi M M, Ahmad U K, Smith R M. J Chromatogr Sci, 1993, 31: 20 |
[9] | Toennesen H H, Karlsen J. J Chromatogr, 1983, 259(2): 367 |
[10] | Ireson C, Orr S, Jones D J L, Verschoyle R, Lim C K, Luo J L, Howells L, Plummer S, Jukes R, Williams M, Steward W P, Gescher A. Cancer Res, 2001, 61: 1 058 |
[11] | Khurana A L, Ho C T. J Liq Chromatogr, 1988, 11(11): 2 295 |
[12] | Heath D D, Pruitt M A, Brenner D E, Rock C L. J Chromatogr B, 2003, 783: 287 |
[13] | Sun X, Gao C, Cao W, Yang X, Wang E. J Chromatogr A, 2002, 962: 117 |
[14] | Liu Baoqi, Hu Xiaozhong, Wang Yuchun, Zhu Baocheng, Ding Liang. Chinese Journal of Instrumental Analysis (刘保启, 胡孝忠, 王玉春,朱宝成,丁良. 分析测试学报), 2004, 23(11): 109 |