欢迎登录材料期刊网

材料期刊网

高级检索

基于中空纤维的液相微萃取集采样、萃取、浓缩于一体,具有成本低,溶剂用量少,易与高效液相色谱、气相色谱、毛细管电泳联用等特点.该技术不仅可实现较高的回收率和富集效率,而且具有突出的样品净化功能,是一种环境友好的样品前处理新技术.该文对基于中空纤维的液相微萃取的装置、操作模式、基本原理及近年来应用研究的进展进行了综述.

参考文献

[1] Raynie D E.Anal Chem,2004,76:4659
[2] Wang Z,Hennion B,Urruty L,Montury M.Food Addit Contam,2000,17(11):915
[3] Cao C F,Wang Z,Urruty L,Pommier J J,Montury M.J Agric Food Chem,2001,49:5092
[4] Arthur C L,Pawliszyn J.Anal Chem,1990,62:2145
[5] Jeannot M A,Cantwell F.Anal Chem,1996,68:2236
[6] Psillakis E,Kalogerakis N.Trends Anal Chem,2002,21(1):53
[7] Liu Jingfu,Jiang Guibin.Chinese Journal of Analytical Chemistry (刘景富,江桂斌.分析化学),2004,32(10):1389
[8] Pedersen-Bjergaard S,Rasmussen K E.Anal Chem,1999,71:2650
[9] Andersen S,Halvorsen T G,Pedersn-Bjergaard S,Rasmussen K E,Tanum L,Refsum H.J Pharm Biomed Anal,2003,33:263
[10] de Jager L S,Andrews A R J.Analyst,2001,126:1298
[11] Müller S,Moder M,Schrader S,Popp P.J Chromatogr A,2003,985:99
[12] Zhu L Y,Zhu L,Lee H K.J Chromatogr A,2001,924:407
[13] Zhao L,Lee H K.Anal Chem,2002,74:2486
[14] Jiang X M,Lee H K.Anal Chem,2004,76:5591
[15] Basheer C,Lee H K.J Chromatogr A,2004,1057:163
[16] Pedersen-Bjergaard S,Rasmussen K E.Electrophoresis,2000,21:579
[17] Zhu L Y,Huey Ee K,Zhao L M,Lee H K.J Chromatogr A,2002,963:335
[18] Halvorsen T G,Pedersen-Bjergaard S,Rasmussen K E.J Chromatogr A,2001,909:87
[19] Hou L,Wen X J,Tu C H,Lee H K.J Chromatogr A,2002,979:163
[20] Ho T S,Halvorsen T G,Pedersen-Bjergaard S,Rasmussen K E.J Chromatogr A,2003,998:61
[21] Ho T S,Pedersen-Bjergaard S,Rasmussen K E.J Chromatogr A,2002,963:3
[22] Pedersen-Bjergaard S,Ho T S,Rasmussen K E.J Sep Sci,2002,25:141
[23] Psillakis E,Kalogerakis N.Trends Anal Chem,2003,22:565
[24] Ho T S,Reubsaet J L E,Anthonsen H S,Pedersen-Bjergaard S,Rasmussen K E.J Chromatogr A,2005,1072:29
[25] Rasmussen K E,Pedersen-Bjergaard S.TrAC,Trends in Analytical Chemistry,2004,23(1):1
[26] Bjorhovde A,Halvorsen T G,Rasmussen K E,Pedersen-Bjergaard S.Anal Chim Acta,2003,491:155
[27] Andersen S,Halvorsen T G,Pedersen-Bjergaard S,Rasmussen K E.J Chromatogr A,2002,963:303
[28] Ho T S,Pedersen-Bjergaard S,Rasmussen K E.Analyst,2002,127(5):608
[29] Rasmussen K E,Pedersen-Bjergaard S,Krogh M,Ugland H G,Gronhaug T.J Chromatogr A,2000,873:3
[30] Pedersen-Bjergaard S,Rasmussen K E.J Sep Sci,2004,27:1511
[31] Wen X J,Tu C H,Lee H K.Anal Chem,2004,76:228
[32] de Jager L S,Andrews A R J.Anal Chim Acta,2002,458:311
[33] Zhao L M,Zhu L Y,Lee H K.J Chromatogr A,2002,963:239
[34] Psillakis E,Kalogerakis N.J Chromatogr A,2003,999:145
[35] Shen G,Lee H K.Anal Chem,2002,74:648
[36] Basheer C,Balasubramanian R,Lee H K.J Chromatogr A,2003,1016:11
[37] Basheer C,Lee H K,Obbard J P.J Chromatogr A,2002,968:191
[38] Basheer C,Obbard J P,Lee H K.J Chromatogr A,2005,1068:221
[39] King S,Meyer J S,Andrews A R J.J Chromatogr A,2002,982:201
[40] Pan H J,Ho W H.Anal Chim Acta,2004,527:61
[41] Psillakis E,Mantzavinos D,Kalogerakis N.Anal Chim Acta,2004,501:3
[42] Lambropoulou D A,Albanis T A.J Chromatogr A,2005,1072:55
[43] Hou L,Shen G,Lee H K.J Chromatogr A,2003,985:107
[44] Jiang X M,Oh S Y,Lee H K.Anal Chem,2005,77:1689
上一张 下一张
上一张 下一张
计量
  • 下载量()
  • 访问量()
文章评分
  • 您的评分:
  • 1
    0%
  • 2
    0%
  • 3
    0%
  • 4
    0%
  • 5
    0%