在采用美国试验与材料学会(ASTM)D6591标准方法测定柴油芳烃含量的过程中,通过光电二极管阵列检测器(PDAD)检测得到的色谱保留时间值及光谱特征吸收曲线,观察柴油中各类芳烃在极性氨基柱上的分离情况;用PDAD检测器考察了根据ASTM D6591确定的反冲洗时间点B对分析结果的影响,结果发现其允许的变化范围为B±0.2 min.在单环芳烃和双环芳烃分界不明显时,用PDAD检测器可以确定其切割点.
参考文献
[1] | Beijing Bureau of Quality and Technical Supervision(北京市技术监督局).DBll/239-2004 |
[2] | Pasadakis N,Gaganis V,Varotsis N.Fuel,2001,80:147 |
[3] | KaminsldM,Kartanowicz R,Przyjazny A.J Chromatogr A,2004,1029:77 |
[4] | Varotsis N,Pasadakis N,Gaganis V.Fuel,1998,77:1495 |
[5] | Tong W Q.Petroleum Products Application Research(童文勤.石油商技),1996,21(3):40 |
[6] | Xu G T,Yuan H F,Lu w z.ACTA Petrolei Sinica:Petroleum Processing Section(徐广通,袁洪福,陆婉珍.石油学报:石油加工).1999,15(2):66 |
[7] | Pasadakis N,Varotsis N.Fuel,2000,79:1455 |
[8] | Keller H R,MassartA D L.Anal Chem Acta,1992,263:21 |
[9] | Chmielowiec J,George A E.Anal Chem,1980,52:1154 |
[10] | Guan Y F,Zhao J H,LiU W M,et al.Chinese Journal of Chromatography(关亚风,赵景红,刘文民,等.色谱).2004,22(5):509 |
[11] | Tao X M.Long Y C,Lu W Z.Chinese Journal of Chroma-tography(陶学明,龙义成,陆婉珍.色谱),1995,13(5):368 |
[12] | ASTM D6591-06 |
上一张
下一张
上一张
下一张
计量
- 下载量()
- 访问量()
文章评分
- 您的评分:
-
10%
-
20%
-
30%
-
40%
-
50%