欢迎登录材料期刊网

材料期刊网

高级检索

分别采用溶液共混和熔融共混的方法制备出聚氨酯/碳纳米纤维复合材料,研究了碳纳米纤维对聚氨酯的热行为和表面微观化学组成的影响,并观察和测定了血小板在复合材料表面的粘附以及血液中血红蛋白浓度、纤维蛋白原浓度的变化,分析了碳纳米纤维对聚氨酯血液相容性的影响.结果表明,引入碳纳米纤维后,聚氨酯复合材料的表面氧含量有不同程度的提高,玻璃化转变温度及熔融温度都发生了改变;血小板在复合材料表面的粘附受到明显的抑制;经血泵循环4 h后,在与聚氨酯复合材料表面接触的血液中,血红蛋白和纤维蛋白原浓度的变化相对减小;复合材料的血液相容性提高.

参考文献

[1] Marie-Claire Belanger, Yves Marois, Raynald Roy, Yahye Mehri, Eric Wagner, Ze Zhang, Martin W. King,Mingjing Yang, Charles Hahn, Robert Guidoin, Selection of a Polyurethane Membrane for the Manufacture of Ventricles for a Totally Implantable Artificial Heart: Blood Compatibility and Biocompatibility Studies,Artifical Organs, 24, 879(2000)
[2] Toshikazu Yoneyama, Kazuhiko Ishihara, Nobuo Nakabayashi, Masashi Ito, Yoshio Mishima, Short-Term In Vivo Evaluation of Small-Diameter Vascular Prosthesis Composed of Segmented Poly (etherurethane)/2-Methacryloxyethyl Phosphorylcholine Polymer Blend, J. Biomed Mater Res (Appl Biomater), 43, 15(1998)
[3] Jung-Sook Bae, Eun-Jin Seo, Inn-Kyu Kang, Synthesis and Characterization of Heparinized Polyurethanes using plasma glow discharge, Biomaterials, 20, 529(1999)
[4] Smith Bavbava AH, Seftone Michael V, Permeability of a Heparin-Poly (vinyl-alcohol) Hydrogel to Thrombin and Antithrombin, J Biomed Mater Res, 22, 673(1988)
[5] Mizumoto D, Nojiri C, Inomata Y, M. Onishi, M. Waki, T. Kido, T. Sugiyama, K. Senshu, K. Uchida, K.Sakai, T. Akutsu, Comparative Blood Compatibility of Polyether vs Polycarbonate Urethanes by Epifluorescent Video Microscopy, ASAIO Journal, 43, M500(1997)
[6] Feng L, Andrade J.D., Protein adsorption on low temperature isotropic carbon: V. How is it related to its blood compatibility? J Biomater Sci Polymer Edn 7, 439(1995)
[7] Alanazi A, Nojiri C, Takayuki K, Noguchi T, Ohgoe Y, Matsuda T, Hirakuri K, Funakubo A, Sakai K, Fukui Y. , Engineering analysis of diamond-like carbon coated polymeric materials for biomedical applications,Artificial Organ, 24, 624(2000)
[8] Deible CR, Beckman E J, Wagner WR. , Creating molecular barriers to acute plate deposition on damaged arteries with reactive polyethylene glycol, J Biomed Mater Res, 41, 251(1998)
[9] XU Haiyan(许海燕),KONG Hua(孔桦),LIN Changyan(蔺嫦燕),Studies onthe blood compatibility ofthe polyurethane/nano-sized carbon composite(聚氨酯基纳米碳复合材料表面的血液相容性研究),Acta Academae Medicinae Sincae(中国医学科学院学报),24,114(2002)
[10] Sheppeck RA and LoGerfo FW, Implantation biology: the host response and biomedical devices (CRC press,Inc., Boca Raton Ann Arbor London Tokyo,1994)p.56
[11] Grunkemeier JM, Tsai WB , Horbett TA, Co-adsorbed fibrinogen and yon Willebrand factor augment platelet procoagulant activity and spreading, J Biomater Sci Polymer Edn, 12, 1(2001)
[12] Feng L and Andrade JD, Protein adsorption on low temperature isotropic carbon: V. How is it related to its blood compatibility? J Biomater Sci Polymer Edn, 7, 439(1995)
上一张 下一张
上一张 下一张
计量
  • 下载量()
  • 访问量()
文章评分
  • 您的评分:
  • 1
    0%
  • 2
    0%
  • 3
    0%
  • 4
    0%
  • 5
    0%