高级检索

采用沉淀法制备了纳米氟羟基磷灰石( FHA),研究了合成温度、初始氟离子浓度和pH值对氟替代的影响.用X射线衍射和红外光谱表征了FHA粉体的物相组成和晶体结构变化,用透射电镜观察了FHA的形貌.结果表明:氟替代会导致晶格参数和键能的变化,随着合成温度或原料中氟浓度的升高,FHA晶粒尺寸和长径比增大;相组成主要受pH值控制,考虑到OH-和F-对羟基空位的竞争,高pH值不利于氟替代.

The nanosized fluorhydroxyapatite (FHA) were synthesized by an aqueous precipitation method.The effects of synthesis temperature,molar ratio of NH4F to Ca(NO3)2.4H2O in the initial reagents[n(F-)/n(Ca2+)] and the pH value on the fluoride substitution were investigated.The phase composition and the change of crystal structure were characterized by X-ray diffraction (XRD) and Fourier transform infrared spectroscope (FT-IR).The morphology of FHA was observed by Transmission electron microscope (TEM).The results show that crystal lattice parameters and bond energy make changes by incorporation of F- ion in the structure.The size and aspect ratio of FHA crystals increase as the precipitation temperature and fluoride concentration.The phase composition of FHA is mainly controlled by the pH value.Considering the possibility of a competition between OH- and F-for occupation of the OH-site,high pH value isn't conductive to the fluoride substitution.

参考文献

[1] Rintoul L,Wentrup-Byme E,Suzuki S,et al.FT-IR spectroscopy of fluoro-substituted hydroxyapatite:strengths and limitations.J.Mater Sci.Mater Med.,2007,18(9):1701-1709.
[2] Eslami H,Solati-Hashjin M,Tahriri M.The comparison of powder characteristics and physicochemical,mechanical and biological properties between nanostructure ceramics of hydroxyapatite and fluoridated hydroxyapatite.Mater Sci.Eng.C,2009,29(4):1387-1398.
[3] Boivin G,Meunier P J.The Metabollic and Molecular Basis of Acquired Disease.London:Bailliere Tindall,1990.
[4] Sogo Y,Ito A,Yokoyama D,et al.Synthesis of fluoride-releasing carbonate apatites for bone substitutes.J.Mater.Sci.Mater Med.,2007,18(6):1001-1007.
[5] Joost M,Thorsen A.A comparison of some effects of fluoride on apatite formation in vitro and in vivo.Cal.Tissue Int.,1984,36(1):690-696.
[6] Wang Y,Zhang S,Zeng X,et al.Osteroblastic cell response on fluoridated hydroxyapatite coatings.Acta Biomater,2007,3(2):191-197.
[7] Zhou H M,Zeng L,Yi D Q,et al.Research on the preparation and bioactivity of FHA coatings.Chinesd J.Mater.Res.,2010,24(6):643-648.
[8] Qu H,Vasiliev A L,Aindow M,et al.Incorporation of fluorine ions into hydroxyapatite by a pH cycling method.J.Mater Sci.:Mater Med.,2005,16(5):447-453.
[9] Chen Y M,Miao X G.Thermal and chemical stability of fluorohydroxyapatite ceramics with different fluorine contents.Biomaterials,2005,26(11):1205-1210.
[10] Cheng K,Weng W J,Wang H M,et al:In vitro behavior of osteoblast-like cells on fluoridated hydroxyapatite coatings.Biomaterials,2005,26(32):6288-6295.
[11] Wang F,Zhang L.Influence of fluorine content on crystal structure of nano-fluorhydroxyapatite powders.Mater Res.Technol.,2008,16(4):559-561.
[12] Zeng L,Zhou H M,Yi D Q,et al.Thermophysical properties and bioacvtivity research of FHA.Funct.Mater,2010,41(1):100-104.
[13] Jha L J,Best S M,Knowles J C,et al.Preparation and characterization of fluoride-substituted apatites.J.Mater Sci.:Mater Med.,1997,8(4):185-189.
[14] Zhang K C,Zhang L H.The science and technology of crystal growth,2nd ed.Beijing:Science Press,1997.
[15] Zhu Q X,Wu J Q.Effective factors of preparation for carbonated hydroxyapatiteby the aqueous precipitation method.J.Chin.Ceram.Soc.,2007,35(6):690-695.
[16] McdowelL H,Gregory T M,Brown W E.Solubility of Ca5(PO4)3OH in the system Ca(OH)2-H3PO4-H2O at 5,15,25 and 37℃.J.Res.Natl.Bur Stand.,1977,81(3):273-281.
[17] Kumar R,Prakash K H,Cheang P,et al.Temperature driven morphological changes of chemically precipitated hydroxyapatite nanoparticles.Langmuir,2004,20(5):196-200.
[18] Zhao Z X,Weng W J,Qu H B,et al.Sol-Gel derived fluorapatite hydroxyapatite films and their solubility.J.Mater Sci.Eng.,2005,23(2):226-229.
[19] Liu Y,Xu H Y.The effects of structural channel inos of apatite on their lattice parameters.J.Mineral Petrol.,2001,21(1):1-4.
[20] Zeng L.The Preparation and Bioactivity Research of FHA and BG/BG-FHA Composite Coating.Changsha:Central South University,Master Thesis,2010.
[21] Weng S.Fourier Transform Infrared Spectrometer,2nd ed.Beijing:Chemical Industry Press,2005.
[22] Zhu Q X,Wu J Q,Xu Q Q.Study on the tructure and thermal stability of hydroxyfluorapatite.Bull.Chin.Ceram.Soc.,2008,27(6):1119-1123.
[23] Penel G,Leroy G,Rey C.Infrared and Raman microspectrometry study of fluor-hydroxy and hydroxyapatite.J.Mater Sci:Mater Med.,1997,8(5):271-276.
[24] Xu T,Liu Y.FTIR research on channel ion of fluoride hydroxyaparite.Light Scattering,2007,19(1):86-90.
[25] Chou X J,Huang M H,Zi W H,et al.The synthesis of hydroxyapatite bioeeramic material by aqueous method.Chin.Ceram.,2004,40(1):20-23.
[26] Huang Z L,Wang D W,Liu Y,et al.The methods and the present progress in preparation of hydroxyapatite (HAP).J.Wuhan Inst.Chem.Tech.,2001,23(3):49-53.
上一张 下一张