建立了测定5-磺基水杨酸的流动注射化学发光新方法.研究了影响化学发光强度的因素,并初步探讨了可能的发光机理.在最佳化学发光条件下,化学发光强度与5-磺基水杨酸浓度在5.0×10-8~2.0×10-5 mol/L范围内呈良好的线性关系,检出限为1.0×10-8 mol/L,对5.0×10-6mol/L的5-磺基水杨酸平行测定9次,其相对标准偏差为2.7%.该法可用于强力霉素废水中5-磺基水杨酸的测定.
参考文献
[1] | WANG Jusi,ZHAO Lihui,KUANG Xin,et al.Biodegradation of Some Aromatic Compounds[J].Acta Sci Circumst,1995,15(9):407-410(in Chinese).王菊思,赵丽辉,匡欣,等.某些芳香化合物生物降解性研究[J].环境科学学报,1995,15(9):407-410. |
[2] | Ministry of Health of the People's Republic of China Pharmacopoeia Commission.The Pharmacopoeia of the People's Republic of China[M].Beijing:People's Medical Publishing,1990:54-59 (in Chinese).中华人民共和国卫生部药典委员会.中华人民共和国药典第二部[M].北京:人民卫生出版社,1990:54-59. |
[3] | Shahrokhian S,Taghani A,Hamzehloei A.Potentiometric Membrane Sensors Based on Zirconyl (Ⅳ) Phthalocyanine for Detection of Sulfosalicylic Acid[J].Talanta,2004,63 (29):371-376. |
[4] | Dong F Q,Wu H L.Determination of Sulfosalicylic Acid[J].Plat Finish,1999,12 (21):35-37. |
[5] | ZHANG Ling,LI Deliang,CUI Jiehu,et al.Simultaneous Determination of Sulfosalicylic Acid and p-Toluene Sulfonic Acid in Doxycycline Waste Water by UV Spectrophotometry[J].J Instrum Anal,2006,25 (4):113-115 (in Chinese).张凌,李德亮,崔节虎,等.紫外光谱法同时测定强力霉素废水中磺基水杨酸与对甲基苯磺酸[J].分析测试学报,2006,25 (4):113-115. |
[6] | Fan X M,Wang S M,Su Z K,et al.Determination of Cinnamic Acid in Human Urine by Flow Injection Chemiluminescence[J].Quim Nova,2011,34(8):1405-1408. |
[7] | Wang J P,Li N B,Luo H Q.Chemiluminescence Determination of Ferulic Acid by Flow-Injection Analysis Using Cerium (Ⅳ) Sensitized by Rhodamine 6G[J].Spectrochim Acta,2008,71(13):204-208. |
[8] | Qu P,Yan S C,Lu H,et al.Flow-Injection Chemiluminescence Determinations for Human Blood Lead Using Controlled Reagent Release Technology[J].Microchim Acta,2008,163 (3/4):321-326. |
[9] | WU Xiongzhi,LU Xiaohui,WANG Lihong.Determination of 5-Suifosalicylic Acid by Flow Injection Chemiluminescence Method Based on Luminol-potassium Permanganate System[J].Chinese J Anal Lab,2010,29 (12):94-97 (in Chinese).吴雄志,吕晓惠,王立红.鲁米诺-高锰酸钾体系化学发光法测定5-磺基水杨酸[J].分析试验室,2010,29(12):94-97. |
[10] | Golcu A,Wheatley R A,Demirelli H,et al.Investigations into the Inhibition of Luminol Chemiluminescence by Some Novel Metal Complexes[J].Curr Anal Chem,2010,6(2):144-153. |
[11] | Shi W B,Hui W,Huang Y M.Luminol-silver Nitrate Chemiluminescence Enhancement Induced by Cobalt Ferrite Nanoparticles[J].Luminescence,2011,26 (6):547-552. |
[12] | Adcoke J L,Francisc P S,Barnett N W.Acidic Potassium Permanganate as a Chemiluminescence Reagent-A Review[J].Anal Chim Acta,2007,601(1):36-39. |
[13] | Zhang H Z,Nie F,Lu J R.Flow Injection Chemiluminescence Method for the Determination of Pentoxyverine Citrate Based on NCS-Dichlorofluorescein Post-chemiluminescence Reaction[J].Spectrochim Acta Part A,2009,72(21):858-862. |
[14] | LIU Ruxia,LU Jiuru.Determination of Cyproheptadine Hydrochloride with Riboflavin Chemiluminescence System[J].Chinese J Anal Chem,2009,37(2):267-270(in Chinese).刘瑞霞,吕九如.核黄素化学发光体系测定盐酸赛庚啶[J].分析化学,2009,37 (2):267-270. |
[15] | YANG Jidong,HUANG Yuming,LIU Shaopu.Flow-Injection Chemiluminescence Analysis of Ammonium Based on the NBS-Ammonium-fluorescein System[J].J Southwest China Normal Univ(Nat Sei),2002,27(3):372-374(in Chinese).杨季冬,黄玉明,刘绍璞.NBS-NH4+-荧光素体系流动注射化学发光法测定铵[J].西南师范大学学报(自然科学版),2002,27(3):372-374 |
[16] | FANG Luqiu,LI Xiaoyan,YANG Jidong.NBS-Fluorescein System for the Determination of Phenformin Hydrochloride by Flow Injection Chemiluminescence[J].J Instrum Anal.2004.23 (2):20-22 (in Chinese).方卢秋,李晓燕,杨季冬.NBS-荧光素体系流动注射化学发光法测定盐酸苯乙双胍[J].分析测试学报,2004,23(2):20-22. |
[17] | FANG Luqiu.FI-chemiluminescence Determination of N1-Dimethylbiguanide Hydrochloride[J].Phys Test Chem Anal,Part B:Chem Anal,2003,39(9):512-514(in Chinese).方卢秋.NBS-荧光素体系流动注射化学发光法测定盐酸二甲双胍[J].理化检验,化学分册,2003,39(9):512-514. |
[18] | Bai H,Nie F,Lu J R.Post-chemiluminescence Phenomenon of NBS-luminol Reactions and Their Applications to Flow Injection Analysis of Piroxicam[J].Anal Sci,2007,23(11):1301-1304. |
上一张
下一张
上一张
下一张
计量
- 下载量()
- 访问量()
文章评分
- 您的评分:
-
10%
-
20%
-
30%
-
40%
-
50%