建立了毛细管电泳-安培检测法测定盐酸去氧肾上腺素(phenylephrine hydrochloride,PHE)、重酒石酸间羟胺(metaraminol bitartrate,MR)和盐酸异丙肾上腺素(isoprenaline hydrochloride,IP)3种拟肾上腺素药物的方法.检测电位为0.950 V(Ag/AgCl为参比电极),硼酸盐浓度为50 mmol/L(pH 10.00),分离电压为18 kV,进样时间为10 s.在最佳实验条件下,3种物质在18 min内达到基线分离,在2~100 μmol/L 浓度范围内峰面积与浓度呈良好的线性关系,线性相关系数不小于 0.999.1.盐酸去氧肾上腺素、重酒石酸间羟胺和盐酸异丙肾上腺素的检出限分别为0.8、0.8和1.0 μmol/L.将所建立的方法应用于针剂样品的分析,结果令人满意.
参考文献
[1] | Jin Y Y.Pharmacology.Beijing:People's Medical Press (金有豫.药理学.北京:人民卫生出版社),2001:39 |
[2] | Yao H,Sun Y,Lin X,et al.Luminescence,2006,21(2):112 |
[3] | Georgiou C A,Koupparis M A.Analyst,1990,115(3):309 |
[4] | Liu H,Feng F,Ma M,et al.J Chromatogr B,2007,858:42 |
[5] | Xu B J,Zhang D T,Shen B C,et al.Chinese Journal of Analytical Chemistry (徐贝佳,张大同,沈报春,等.分析化学),2007,35(1):55 |
[6] | Abdolraouf S M,Seyed K H N D.Spectrochim Acta,Part A,2010,75(4):1270 |
[7] | Huang F,Jin G,Liu Y,et al.Talanta,2008,74(5):1435 |
[8] | Wang C Q,Wang H,Liu Y M.Chinese Chemical Letters,2007,18(4):452 |
[9] | Cheng H,Wu J H,Chen R S,et al.Chinese Journal of Analytical Chemistry (程寒,吴剑虹,陈荣生,等.分析化学),2008,36(1):1 |
[10] | Gomez M R,Olsina R A,Martínez L D,et al.J Pharm Biomed Anal,2002,30:791 |
[11] | Wei S,Song G,Lin J M.J Chromatogr A,2005,1098:166 |
[12] | Gallego J M L,Arroyo J P.J Sep Sci,2003,26(9):947 |
[13] | Wang Z,Sun Y,Sun Z.J Chromatogr A,1996,735:295 |
[14] | Miku(s) P,Valá(s)ková I,Havránek E.J Pharm Biomed Anal,2003,33(2):157 |
[15] | Wang H,Gu J L,Hu H F,et al.Anal Chim Acta,1998,359:39 |
[16] | Hedeland Y,Hagl(o)f J,Beronius P,et al.Electrophoresis,2006,27(22):4469 |
[17] | Servais A C,Chiap P,Hubert P,et al.Electrophoresis,2004,25(10):1632 |
上一张