建立了一种测定胶黏剂中6种丙烯酸酯和甲基丙烯酸酯类残余单体的分析方法.样品经100℃、30 min顶空加热后,通过DB-WAX色谱柱(30m×0.25mm×0.25μm)分离和质谱选择离子模式检测,内标法定量.结果表明,6种残余单体能达到良好的分离,检出限(信噪比为3)为0.069~0.096 mg/kg,定量限(信噪比为10)为0.23~0.32 mg/kg,平均回收率为96.0%~104.6%,相对标准偏差(RSD)小于7.2%.该方法操作简便、准确、重复性好、灵敏度高,可用于胶黏剂中丙烯酸酯和甲基丙烯酸酯类残余单体的快速测定.
参考文献
[1] | Fu W Z.Journal of Labour Medicine(傅慰祖.劳动医学),1998,15(4):Appendix 3 |
[2] | Zhao M.Practical Handbook on Toxicity and Safety of Adhesives.Beijing:Chemical Industry Press(赵敏 胶黏剂毒性与安全实用手册.北京:化学工业出版社),2004:142 |
[3] | GB/T 9685-2008 |
[4] | Xia Q L,Liu H M,Ding L,et al.Tobacco Science&Technology(夏巧玲,刘惠民,丁丽,等.烟草科技),2009(8):35 |
[5] | Bu W,Li J.Technology&Development of Chemical Industry(卜伟,李江.化工技术与开发),2007,36(6):38 |
[6] | Gu H D,Shi Y S.Chemical Analysis and Meterage(顾海东,史永松.化学分析计量),2002,11(1):28 |
[7] | Huang L P,Liu Z,Jiang H.Environmental Monitoring in China(黄凌萍,刘真,江红.中国环境监测),2003,19(2):35 |
[8] | Yang J L,Bian H,Hong Y C,et al.Ion Exchange and Adsorption(杨佳玲,边晖,洪育春,等.离子交换与吸附),2010,26(2):169 |
[9] | Wu P,Miao J Y.Chemical Analysis and Meterage(吴鹏,缪建洋.化学分析计量),2006,15(3):57 |
[10] | Chen L,Li Q Z,Wang M,et al.Chinese Journal of Chromatography(陈玲,李钦祖,王敏.色谱),1993,11(5):311 |
[11] | Wang C Y F,Gerhart B,Smith C G.Anal Chem,1995,67(20):3681 |
[12] | Steichen R J.Anal Chem,1976,48(9):1398 |
[13] | Hu J,Luo H F,Wang Y Z,et al.Chinese Journal of Pharmaceuticals(胡婧,罗华菲,王雅珍,等.中国医药工业杂志),2010,41(2):120 |
[14] | Wilkinson L B,Norman C W,Buettner J P.Anal Chem,1964,36(9):1759 |
[15] | Lü Q,Zhang Q,Kang S Y,et al.Chinese Journal of Chromatography(吕庆,张庆,康苏媛,等.色谱),2010,28(8):800 |
[16] | Shen H Y,Zhao Y G,Huai M M,et al.Chinese Journal of Chromatography(沈昊宇,赵永纲,怀明敏,等.色谱),2009,27(1):63 |
[17] | Xu Y H,Zhu B H,Zhong X H,et al.Chinese Journal of chromatography(许瑛华,朱炳辉,钟秀华.等.色谱),2010,28(1):73 |