欢迎登录材料期刊网

材料期刊网

高级检索

为了能够更好地实现对液晶光学相控阵的移相分布特性进行高精度的测量,本文针对傅里叶四分之一波片法的测试精度进行理论仿真和试验验证.仿真结果表明,该方法测试误差小于0.08°,采用标准二分之一波片对其进行验证,实验结果表明重复精度小于0.3°.因此,针对液晶光学相控阵波控数据0.5°移相控制精度要求,傅里叶四分之一波片法的测试精度和重复精度能够满足移相测量精度要求.

With the purpose of highly precise measuring the phase delay distribution of liquid crystal optical phased array,the accuracy and precision of the measuring method of Fourier Quarter-Plate are both analyzed theoretically and evaluated experimentally.Numerical simulations indicate that the error of this method is smaller than 0.3°when we assumed a couple of ordinary parameters on the system.A practical experiment on a standard half wave plate is also accomplished showing that the accuracy is smaller than 0.3°and the repeat precision is also smaller than 0.3°.Simulations and experiments show a good agreement with each other so that a demonstration Fourier Quarter-Plate method can meet the requirement on phase delay measurement better than 0.5°on liquid crystal optical phased array.

参考文献

[1] 汪相如;谭庆贵;黄子强;孔令讲;杨若夫;幺周石.液晶光学相控阵的双波束成形和2维扫描技术[J].激光技术,2013(5):631-635.
[2] Liu Rui-Xue;Zheng Xian-Liang;Li Da-Yu;Xia Ming-Liang;Hu Li-Fa;Cao Zhao-Liang;Mu Quan-Quan.Retinal axial focusing and multi-layer imaging with a liquid crystal adaptive optics camera[J].中国物理B(英文版),2014(9):252-260.
[3] 张亚超;胡立发;彭增辉;宣丽.液晶波前校正器过驱动矩阵的测量方法研究[J].液晶与显示,2014(5):709-715.
[4] Xiangjie Zhao;Cangli Liu;Dayong Zhang;Yongquan Luo.Direct investigation and accurate control of phase profile in liquid-crystal optical-phased array for beam steering[J].Applied optics,201329(29):7109-7116.
[5] 索国国;汪相如;黄子强;汤镇辉;杜静.傅里叶λ/4波片双折射检测方法[J].激光技术,2016(1):131-135.
上一张 下一张
上一张 下一张
计量
  • 下载量()
  • 访问量()
文章评分
  • 您的评分:
  • 1
    0%
  • 2
    0%
  • 3
    0%
  • 4
    0%
  • 5
    0%