以1-亚硝基-2-萘酚为萃取剂, 以90℃熔融萘作稀释剂萃取痕量钯 (Ⅱ), 萘相中钯经氯仿溶解后用光度法测定其含量. 实验条件下络合物能从pH=0.8~11.0范围内定量萃入萘中, 络合物波长λmax=440 nm, 摩尔吸光系数ε440=2.41×104 L.mol-1.cm-1, 组成比Pd∶HR=1∶2, 萃取反应平衡常数Kex=6.31×1011. 钯量在0.48~34 μg/10 ml范围内符合朗伯-比耳定律, 检测限为0.044 μg/10 ml. 同时确定了光度法测定的最佳条件及常见阴阳离子的干扰允许量. 利用该法进行合成样与实际样中钯含量的测定, 结果满意.

参考文献

[1] Fujinaga T;Kuwamoto T;Nagayama E .[J].Talanta,1969,16:1225.
[2] Sharma RK. .SOLID-PHASE EXTRACTION OF TRACE METAL IONS USING LOW-MELTING EXTRACTANTS [Review][J].Microchemical Journal: Devoted to the Application of Microtechniques in all Branches of Science,1995(3):289-311.
[3] Gao J Z;Peng B;Fan H Y et al.[J].Talanta,1996,43:1721.
[4] Gao J Z;Peng B;Fan H Y et al.[J].Talanta,1997,44:837.
[5] Sharma R K;Garg B S .[J].Annales de Chimie,1991,81:257.
[6] Sharma R K;Sharavah K;Sinclhwani S K .[J].Analyst,1987,112(02):175.
[7] Fujinaga T;Puri B K .[J].Indian Journal of Chemistry Section A:Inorganic,Bio-inorganic,Physical,Theoretical and Analytical Chemistry,1976,14(01):72.
[8] Fujinaga T;Sataka M;Yonekubo T .[J].Japan analyst,1971,20(10):1255.
[9] Fujinaga T;Sataka M;Yonekubo T .[J].Talanta,1972,19(05):689.
[10] Chang L F;Sataka M;Kumamoto T et al.[J].Microchemical Journal,1986,33:46.
[11] Wasey A;Bansal R K;Puri B K et al.[J].Analyst,1984,109:601.
[12] Puri B K;Kumar A;Sethi C L .[J].Chemical Scripta,1982,19:205.
[13] Ross L E;Kesser G;Kucera E T .[J].Analytical Chemistry,1960,32:1367.
[14] 杭州大学化学系分析化学教研室.分析化学手册 (第三分册),电化学分析与光学分析[M].北京:化学工业出版社,1983:438.
[15] З Марченко.Фотометрическоеолределениезлементов[M].ИздателъствоМИРМосква,1971:328.