Pr部分替代Ca可以在Bi-2223的超导层中引起局域缺陷(简称Pr离子缺陷),本文分析了不同含Pr量的Bi-2223/Ag带材在垂直于带面的外场下电阻转变特性,研究了其磁通钉扎势垒的变化规律.结果表明:Pr离子缺陷显著提高了Bi-2223带材的磁通钉扎势垒(U).不同含Pr量样品的磁通钉扎势垒(U)均满足U/(1-T irr/Tc0)(1/Hα的规律,其不同α值反映了样品中不同的磁通蠕动方式.在不含Pr离子缺陷的样品中,磁通主要以双弯结的方式进行蠕动, 含Pr离子缺陷的样品中磁通蠕动主要以直接剪切的方式进行.
参考文献
[1] | P W Anderson .[J].Physical Review Letters,1962,9:309. |
[2] | P W Anderson;Y B Kim .[J].Reviews of Modern Physics,1964,36:39. |
[3] | M Tinkham .[J].Physical Review Letters,1988,61:1658. |
[4] | T T M Palstra et al.[J].Applied Physics Letters,1989,54:763. |
[5] | J Z Sun et al.[J].Applied Physics Letters,1989,54:663. |
[6] | T T M Palstra et al.[J].Physical Review Letters,1988,61:1662. |
[7] | J T Kucera et al.[J].Physical Review B,1992,46:11004. |
[8] | R Noetzel;K Westerholt .[J].Physical Review B,1998,58:15108. |
[9] | A K Pradhan et al.[J].Physical Review B,2001,64:172505. |
[10] | K C Woo et al.[J].Physical Review Letters,1989,63:1877. |
[11] | V Geshkenbein et al.[J].Physica C,1989,162-164:239. |