利用自制的微型碱式滴定管进行了酸碱滴定和配位滴定的微型试验研究.通过酸碱滴定试验,将自制的各种规格的微型碱式滴定管与常规碱式滴定管的分析结果进行了比较,优选出最佳装置,并将其应用于常量铅、铋的测定.结果表明,用微型滴定管所得测定结果的准确度和精密度与常量滴定法相当,并克服了常量碱式滴定管近终点液滴不易控制,废液排放量大及试剂用量大等缺点,可节省大量试剂和时间,同时大大减轻了铅等试剂对环境的污染.

Micro-titration experiments based on the acid-base titration and complexometric titration were explored through a self-made device of micro basic burette. A comparison between these micro basic burettes of various specification and conventional macro basic burettes was done through experiments of acid-base titration. The optimum device was obtained and used in the determination of macro lead and bismuth. The results show that the accuracy and precision of the microburette are equivalent to those of conventional macro burette. Furthermore, it overcomes some shortages of macro titration, for instance, the end of titration is not easy to control, or a large amount of reagents has to be consumed and discharged into the environment. The device can reduce reagent dosage, experiment time and especially environmental pollution caused by reagents like lead.

参考文献

[1] 倪静安;高世萍;李运涛.无机及分析化学实验:第一版[M].北京:高等教育出版社,2007:166-167.
[2] 武汉大学化学与分子科学学院实验中心.分析化学实验:第一版[M].武汉:武汉大学出版社,2003:100-102.
[3] 李方实;俞斌.无机及分析化学实验:第一版[M].南京:东南大学出版社,2002:149-150.
[4] 北京大学化学系分析化学教研组.基础分析化学实验:第一版[M].北京:北京大学出版社,1993:177-178.
[5] 汤宝珍;樊永年;范尚立 .络合滴定法连续测定高温超导体中铋和铅[J].冶金分析,1992,12(04):60.
[6] 薛光荣,夏敏勇.FAAS法快速测定铜银合金中铅铋和锑[J].贵金属,2009(01):49-52.
[7] 唐华应,方艳,刘惠丽,张映霞.电感耦合等离子体原子发射光谱法测定钨铁合金中铅锡铋[J].冶金分析,2007(12):43-45.
[8] 蔡成翔.毛细滴管-吸量管数滴微型滴定法现场快速测定水的总硬度[J].工业水处理,2006(12):70-73.
[9] 沈文闻,蔡成翔.毛细滴管数滴微型滴定法测定碘离子[J].分析科学学报,2007(04):492-494.
[10] 沈文闻.毛细滴管计滴碘量法测定锑配合物中锑含量[J].冶金分析,2009(02):77-80.
[11] 陈剑宏;徐华华.滴定分析的微量化[J].化学通报(印刷版),1992(04):45-46.