欢迎登录材料期刊网

材料期刊网

高级检索

研究了一种离子色谱抑制电导法测定冶金浸出液中氯离子的方法.以SH-AC-1型阴离子分离柱(10μm,4.6 mm×250 mm)为色谱柱,2.5 mmol/L碳酸钠+3.5 mmol/L碳酸氢钠的混合溶液为淋洗液,在柱温为25℃,流速为2.0 mL/min,进样量为100μL的条件下进行检测,氯离子检出限为0.51μg/L,线性范围为0.002~15.0 mg/L,线性方程为Y=1.2×106X-1.1×105(Y:峰面积;X:质量浓度mg/L),线性相关系数为0.999 8.将本方法应用于铜氨浸出液中氯离子的测定,相对标准偏差(n=11)为6.9%,加标回收率为104%.

参考文献

[1] 烟伟.混合铜矿的常压氨浸与高压氨浸[J].湿法冶金,2001(02):76-78.
[2] 张保平,唐谟堂.NH4Cl-NH3-H2O体系浸出氧化锌矿[J].中南工业大学学报(自然科学版),2001(05):483-486.
[3] 牟世芬;刘克纳;丁晓静.离子色谱方法及应用[M].北京:化学工业出版社,2006:4-6.
[4] Yasunari Noguchi;Liang Zhang;Toshihisa Maruta .Simultaneous determination of fluorine, chlorine and bromine in cement with ion chromatography after pyrolysis[J].Analytica chimica acta,2009(1/2):106-109.
[5] Pereira JSF;Diehl LO;Duarte FA;Santos MFP;Guimaraes RCL;Dressler VL;Flores EMM .Chloride determination by ion chromatography in petroleum coke after digestion by microwave-induced combustion[J].Journal of chromatography, A: Including electrophoresis and other separation methods,2008(2):249-252.
[6] Magdalena Biesaga;Nicole Schmidt;Andreas Seuberu .Coupled ion chromatography for the determination of chloride,phosphate and sulphate in concentrated nitric acid[J].Journal of Chromatography A,2004,1026(1-2):195-200.
[7] Thangavei S;Dash K;Dhavile S M et al.Determination of traces of chloride and fluoride in H2SO4,H3PO4 and H3B3O3 by in situ analyte distillation-ion chromatography[J].Journal of Chromatography A,2005,1074(1-2):229-233.
[8] Sangita D Kumar;Tripathi V S;Niyoti Shenoy et al.Chloride analysis in magnesium metal using ion chromatography with conduetometric detection[J].Journal of Chromatography A,2004,1046(1-2):155-158.
[9] Po Chen;Wan-Zhi Wei;Shou-Zhou Yao .Different valency chlorine species analysis by non-suppressed ion-chromatography with double cell quartz crystal detector[J].Talanta: The International Journal of Pure and Applied Analytical Chemistry,1999(3):571-576.
上一张 下一张
上一张 下一张
计量
  • 下载量()
  • 访问量()
文章评分
  • 您的评分:
  • 1
    0%
  • 2
    0%
  • 3
    0%
  • 4
    0%
  • 5
    0%