惰气熔融法定量分析镁中气体含量必须结合合适的浴料/助熔剂,氧、氢和氮分别测定,才能有效地减少镁挥发物对分析结果的干扰,实现定量准确测定.应用特制的Sn-Ni-FeCu-C五元浴测定纯镁粉、镁-铝粉、镁粒和镁锭样品中氧含量,相对标准偏差(RSD,n=3)小于31.5%;用纯物质Mg(OH)2标定时,氧的回收率达97.1%.应用锡助熔剂/浴料结合较低的分析功率测定纯镁粉、镁-铝粉和镁锭中氢,相对标准偏差(RSD,n=6)小于35.7%,采用Mg(OH)2标定,氢的回收率达96.9%.应用镍助熔剂测定纯镁粉、镁-铝粉和镁锭中氮,相对标准偏差(RSD,n=3)小于23.6%,采用纯物质Mg3 N2标定,氮的回收率达99.2%.应用钢标祥监控镁污染情况,确保镁中气体分析数据的可靠性.
参考文献
[1] | Bryce L Twitty;Kenneth M Fritz .Internal standard techniques for determination of oxygen in magnesium,steel,and titanium by activition analysis[J].Analytical Chemistry,1967,39(04):527-529. |
[2] | Talbot,D.E.J .Effects of hydrogen in aluminium,magnesium,copper,and their alloys[J].International Metallurgical Reviews,1975,20(19):166-184. |
[3] | 朱跃进;李素娟 .脉冲红外法测定镁中氧[J].分析试验室,2000,19(增刊):30-31. |
[4] | GJB 5909-2006.铝及铝合金中氢的测定:加热提取热导法[S]. |
[5] | 李岩;王强 .铝钒合金中氧含量测定方法的研究[J].分析试验室,2010,29(增刊):331-333. |
[6] | LECO.Instruction manual of TC-436 nitrogen/oxygen determinator[M].,1994 |
[7] | LECO.Instruction manual of RH-404 hydrogen determinator[M].,1996 |
[8] | 朱跃进 .五元浴在氧氮测定中的应用[J].分析试验室,2004,23(增刊):207-209. |
[9] | ДФ切尔涅茹;黄良余;严名山.有色金属及其合金中的气体[M].北京:冶金工业出版社,1998 |