提出了亚甲蓝法测定微量硫化物新的显色过程,研究了用普通分光光度法和全差示分光光度法测定微量硫化物的条件.采用普通光度法,标准曲线为A=1.28ρ+0.002,r=0.999 5,表观摩尔吸收系数为4.06×104L/(mol@cm),线性范围为0~0.9mg/L;采用全差示分光光度法,标准曲线为A=7.0ρ+0.004,r=0.999 6,表观摩尔吸收系数为2.2 × 105 L/(mol@cm),线性范围为0~0.14mg/L.与原亚甲蓝法相比,灵敏度显著提高,显色反应迅速完成.两种方法的检测限均为1.0ng/ml;测定100ng/ml S2-,相对标准偏差为1.9%(n=10).实验了各种干扰离子对硫化物测定的影响,提出了消除干扰离子的方法.利用该方法测定环境样品中微量硫化物,结果令人满意.
参考文献
[1] | Zenon Pawlak;Agnieszka S. Pawlak .Modification of iodometric determination of total and reactive sulfide in environmental samples[J].Talanta: The International Journal of Pure and Applied Analytical Chemistry,1999(2):347-353. |
[2] | Wei Fusheng;Zhu Yurei;Yin Fang et al.Indirect spectrophotometric determination of sulphide with the ternary complex system Ag(I)-phen-BPR[J].TALANTA,1981,28:853-854. |
[3] | Michael D Kester;Paul M Shiundu;Adrian P Wade .Spectrophotometric method for determination of sulfide with iron ( Ⅲ ) and nitrilotriacetic acid by flow injection[J].Talanta,1992,39(03):299-312. |
[4] | Ghasemi J.;Mohammadi DE. .Kinetic spectrophotometric determination of sulfide using whole kinetic curve and a fixed time method[J].Microchemical Journal: Devoted to the Application of Microtechniques in all Branches of Science,2002(1):1-8. |
[5] | D J Leggett;N H Chen;D S Mahadevappa .Flow injection method for sulfide determination by the methylene blue method[J].Analytical Biochemistry,1981,128:163-168. |
[6] | 黄兰芳;汪炳武 .对氨基二乙基苯胺全差示光度法测定微量铬[J].分析化学,1997,25(02):208-211. |
[7] | J C Miller;J N Miller.Statistics for Analytical chemistry[M].New York:Ellis Horwood,1984 |