用动电位慢扫描法研究了钼系缓蚀剂在去离子水中和含5ppm Cl-的去离子水中对A3钢的缓蚀性能,并与200ppm的K2CrO4在同样条件下对A3钢的缓蚀性能作了比较.在5ppm Cl-的去离子水的敞开体系中,100ppm Na2MoO4的缓蚀性能与200ppm的K2CrO4相当;复合缓蚀剂Na2MoO4(12ppm)+NaNO2(23ppm)+ZnSO4(5ppm)+十二酰基肌氨酸钠(100ppm)的性能优于200ppm K2CrO4; 复合缓蚀剂Na2MoO4(86ppm)+Na2SiO3(114ppm)的性能显著优于200ppm的K2CrO4.
参考文献
[1] | Pryor M J;Cohen M.[J].Journal of the Electrochemical Society,1953(100):203. |
[2] | Alexander D B;Moccan A A .[J].Corrosion,1993,49(11) |
[3] | 张淑玲 等.[J].腐蚀与防护,1992,13(04) |
[4] | Al-Borno A et al.[J].CORROSION,1989,45(12):970-975. |
[5] | Vukasovich M S;Farr J P .[J].MP,1986,25(05):9. |
[6] | Alexander D B;Moccan A .[J].Corrosion,1993,49(11):923-926. |
[7] | Burda P A.Molybdates as Chromate Replacement for Closed Cooling Water Systems in Nuclear Industry[A].Houston, TX: NACE,1992:118. |
[8] | 麦秀芬.[J].石油化工腐蚀与防护,1992(01):13-18. |
[9] | 莫自如.MBT、HEDP、Zn2+与钼酸盐协同缓蚀效应的研究[J].腐蚀科学与防护技术,1992(04):301. |
[10] | Qian Y J et al.[J].Br Corrosion,1987,J22(04):268-271. |
[11] | 杨文治;黄魁元;王清.缓蚀剂[M].北京:化学工业出版社,1989:119-120. |
[12] | Davis J R.Metals Handbook[M].Metals Park, OH:ASM International,1987 |