用透射电镜(TEM)及电子背散射衍射(EBSD)技术对电铸铜药型罩经爆破变形(相对形变达900%,形变速度达104-107s-1)前后的微观组织及内部晶粒的晶体取向分布进行了分析比较.实验结果表明电铸铜药型罩的高速变形过程是一个动态回复和动态再结晶过程.
参考文献
[1] | Jamet F.Investigation of shaped charge jets using X-ray flash diffraction[A].:1984-1910. |
[2] | Jamet F;Charon R.A flash X-ray diffraction system for shaped charge jets analysis[A].,1986 |
[3] | Zemow L;Lowry L.Shock-wave and high strain-rate phenomema in materials[M].Marcel Dekker. New York,1992:46. |
[4] | Engler O;Gottstein G .[J].Steel Research International,1992,63:413. |
[5] | Engler O;Gottstein G;Pospiech J;Jural J .[J].Materials Science Forum,1994,157:259. |
[6] | 田文怀;胡士廉;孙起 .[J].电子显微学报,1999,18:5. |
[7] | 刘晋春;张家齐.特种加工[M].北京:机械工业出版社,1994:118. |
[8] | 胡士廉,田文怀,周登陵,孙起.电子背散射衍射对电铸药型罩织构的定量分析[J].兵器材料科学与工程,2000(03):31-35,50. |
[9] | 胡士廉;田文怀;孙起 .[J].兵器材料科学与工程,1999,22:35. |
[10] | Kuhlmann-wilsdorf D .[J].Physica Status Solidi A,1989(104):1. |
[11] | Kuhlmann-wilsdorf D .[J].Materials Science and Engineering,1989,A113:1. |
[12] | Bay B;Hansen N;Hughes D A .Kuhlmann-wilsdorf D[J].Acta Metallurgica Et Materialia,1992,40(02):20. |