为了研究血液灌流用多肽吸附剂以治疗尿毒症,本文以戊二醛为交联剂,用反向悬浮聚合方法制备了交联壳聚糖吸附剂,继而用NaBH4还原处理,并对其还原效果和溶胀性能作了表征.吸附实验结果表明,吸附剂对选取的六种多肽均有不同程度的吸附;随着多肽链的增长,吸附剂对其的吸附能力体现出先增强后减小的趋势;对分子量为1 100的垂体后叶素吸附效果最好.同时,吸附动力学曲线表明,随着肽分子量的增大,达到吸附平衡的时间也延长,对六种肽的吸附分别在0.6~2 h内达到平衡.

参考文献

[1] GIOVANETTIS;BARSOTTI G .Uremicintoxication[J].NEPHRON,1975,14:123-133.
[2] ZIMMERMANL;JORNVALL H;BERGSTROM J et al.Characterization of middle compounds[J].International Journal of Artificial Organs,1980,4:33-35.
[3] MAUCHIH;NAKAHASHI H .Middle-sized peptides in the blood of patients with uremia[J].Nephrology,1983,33:232-237.
[4] MAUCHIH;NAKAHASHI H J .Profiling of urinary medium sized peptides in normal and uremic urine by high-performance liquid chromatography[J].Chromatography,1982,233:107-133.
[5] FLANAGANRWJ;MURPHY R F;BUCHANAN K D .Circulating forms of glucagon and related peptides in normal subjects and uremic patients[J].Biochemical Society Transactions,1980,8:426-427.
[6] MATTAEID;LUDWIG-KOLN H;KRAMER P et al.Changes of plasma hormone levels in hemofiltration[J].International Journal of Artificial Organs,1983,6:21-24.
[7] 储结根,袁直,腾欣莲,宓怀风,何炳林.尿毒症患者血清及正常人尿液内中分子物质的分离分析[J].中国科学(B辑),2000(03):250-255.
[8] VanholdeRR;DE S R;GLORIEUX et al.SurvivalofhemodialysisPatientsanduremictoxinremoval[J].Artificial Organs,2003,27(03):218-223.
[9] Clark WR;Winchester JF .Middle molecules and small-molecular-weight proteins in ESRD: Properties and strategies for their removal.[J].Advances in renal replacement therapy,2003(4):270-278.
[10] Chu J;Yuan Z;Liu X;Wu Q;Mi H;He B .Separation of six uremic middle molecular compounds by high performance liquid chromatography and analysis by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.[J].Clinica chimica acta: International journal of clinical chemistry and applied molecular biology,2001(2):95-107.
[11] VADIMD;LUDMILA P;MARIA T et al.Polymeric adsorbent for removing toxic proteins from blood of patients with kidney failure[J].Journal of Chromatography B,2000,739:73-80.
[12] RONCOC;BRENDOLAN A;WINCHESTER J F et al.The Next Step from High-Flux Dialysis:Application of Sorbent Technology[J].Blood Purification,2001,19:260-263.