用电化学动电位再活化法与草酸浸蚀法研究了1Cr18Ni9Ti不锈钢的晶间腐蚀敏感性,并对动电位再活化法用于评价不锈钢晶间腐蚀敏感性的各种判据进行了综合分析.实验结果表明:各种判据与材料的敏化程度有良好的对应关系,且能灵敏定量地反映低敏化材料的晶间腐蚀敏感性的变化.各种判据中电流比ir/ia,电量比Qr/Qa的数据波动性小,重现性好;而再活化电流ir与再活化电量Qr的数据波动较大,重现性较差.电量判据(包括再活化电量Qr及电量比Qr/Qa)较电流判据(包括再活化峰峰值电流ir及电流比ir/ia)能更灵敏地反映材料晶间腐蚀敏感性的变化.

The susceptibility to intergranular corrosion(IGC) for 1Cr18Ni9Ti stainless steel has beenstudied by the electrochemical potentiodynamic reactivation (EPR) method and the oxalic acid etch test.Different criteria used in EPR test to evaluate the tendency of IGC have been analyzed in detail. Allcriteria are well correlated with the degree of sensitization. With increasing sensitization time, the valueof criteria increases. Furthermore, all criteria can sensitively and quantitatively reflect the difference ofmaterial with lower sensitization. In all criteria, the current ratio ir/ia and charge ratio Qr/Qa have betterrepeatability than the reactive current ir or the reactive charge Qr. The criteria of charge (Qr, Qr/Qa)are more sensitive than the criteria of current (ir, ir/ia).

参考文献

[1] Duffaut F;Ponzet J P;Lacombe P .Potentiostatic study of structura modifications caused in a Ni-Cr-Fe alloy by heat treatment at 650℃[J].Corrosion Science,1966,6(02):83-85.
[2] Clarke W L;Carlson P C .[J].Nondestructive measurement of sensitization of stainless steel relation to high temperature stress corrosionbehavior,1980,19(03):16-23.
[3] Akashi M;Kawamoto T .The effect of molybdenum addition on SCC susceptibility of stainless steels in oxygenated high temperature water[J].Corrosion Engineering,1978,27(04):165-171.
[4] 方智.电化学动电位再活化法评价308L不锈钢的晶间腐蚀敏感性[J].腐蚀科学与防护技术,1996(02):87.
[5] Cihal V .Advances in the potentiodynamic reactivation method[J].WerKstoffe und Korrosion,1986,37(11):587-591.
[6] Scully J R;Kelly R G .An electrochemical test for detecting the intergranular corrosion auaceptibility of a duplex stainless steel[J].Corrosion,1986,42(09):537-542.
[7] Frangini S;Mignone A .Modified electrochermical potentiokinetic reactivation mothod for detecting sensitization in 12wt% Cr ferriticstainless steels[J].Corrosion,1992,48(09):715-726.
[8] ASTMBook of Standards[S].A262, ASTM, Philadelphia, Pennsylvania,1981.