本文设计加工了细水雾发生器,并且应用三维LDV/APV(Adaptive Phase/Doppler Velocimeter)系统对其产生的细水雾雾场特性参数做了有效的测量,并在此基础上进行了细水雾抑制液体火有效性的模拟实验.利用热像仪、热电偶和摄像机等仪器研究了这种细水雾抑制熄灭煤油火和酒精火的过程.实验结果表明细水雾技术具有应用在灭火系统上的可行性,并具有优越的特点.
参考文献
[1] | Grant G, Brenton J, Drysdale D. Fire suppression by water sprays [J]. Progress in Energy and Combustion Science, 2000, 26:79-130 |
[2] | Atreya A et al. A study of the chemical and physical mechanisms of fire suppression by water [C] // 6th International Symposium, 1999, 5-9 |
[3] | Qin Jun,Wang Xishi, Liu Jianghong et al. Design of APV optics system in measurement of flow field [J]. Chinese Journal of Quantum Electronics(量子电子学报),2001,18(1):56-61(in Chinese) |
[4] | Qin J,Liao G X,Wang X S et al.Experimental study on the fire whirlwind temperature measurment by infrared thermography [J].Laser & Infrared(激光与红外),2002,32(1):33-36(in Chinese) |
[5] | Gerand G et al. The capabilities and limitations of tatal flooding water mist fire suppression system in machinery space applications [J]. Fire Technology, 2000, 36(1) |