高级检索

在介绍一种采用钽酸锂热释电探测器实现的实时测温系统的基础上,着重讨论了探测器系统本身的辐射对该系统测温精度的影响.提出了抑制探测器系统本身的辐射对该系统测温精度影响的三条措施:一是对探测器进行水冷;二是采用一带宽为150 nm的窄带干涉滤光片;三是进行电气补偿并进行了一些必要的分析与讨论.同时实验也表明,在采取上述抗干扰措施后,在要求的测温范围400℃~1200℃内,测温精度符合设计要求.

参考文献

[1] Khan M A, Allemand C, Eagar T W. Noncontact temperature measurement I: interpolation based techniques [J].Rev. Sci. Instrum., 1991, 62(2): 392-402
[2] Hahn J W, Rhee C. Reference wavelength method for a two-color pyrometer [J]. Appl. Opt., 1987, 26(24):5276-5279
[3] Hunter G B, Allehand C D, Eager T W. Multiwavelength pyrometer [J]. Opt. Eng., 1985, 24(6): 1081-1085
[4] Dewitt D P. Inferring temperature from optical radiation measurement [J]. Opt. Eng., 1986, 25(4): 596-601
[5] Krivtzum V, Grass B, Hergenroder R, et al. Temperature measurement of liquids by differential absorption of two diode laser: application of contactless optical detection in isotachophoresis [J]. Appl. Spectro., 2001, 55(9):1251-1258
[6] Fan C H, Longtin J P. Laser-based measurement of temperature or concentration change at liquids surfaces [J].Journal of Heat Transfer, Transactions ASME, 2000, 122(4): 757-762
[7] Kee H H, Lees G P, Newson T P. Technique for measuring distributed temperature with 35 cm spatial resolution utilizing the landau-placzek ratio [J]. IEEE Photonics Technology Lett., 2000, 12(7): 873-875
[8] Hu Ruihua, Luan Song, Sun Ningke. Radiation thermometer for determining temperature and emissivity [J].Infrared Technology(红外技术),1998, 20(2): 21-22 (in Chinese)
[9] Shi Deheng, Huang Guoqing, Liu Yufang, et al. Optimization of a practical real-time temperature measurement system [J]. Acta Optica Sinica(光学学报),2003, accepted (in Chinese)
[10] Shi Deheng, Huang Guoqing, Liu Yufang. worhing wavelength optimization of a practical real-time temperature measurement system [J]. Chinese Journal of Lasers(中国激光),2003, 30(6): 545-550 (in Chinese)
[11] Shi Deheng, Xu Qifu, Chen Yuke, et al. Measures on improving sampling accuracy of temperature teal-time measurement system [J]. Laser Journal(激光杂志),2001, 22(1): 41-43 (in Chinese)
[12] Shi Deheng, Liu Yufang, Sun Jinfeng, et al. Wavelength bandwidth optimization of a practical real-time temperature measurement system [J]. Acta Optica Sinica(光学学报),2003, accepted (in Chinese)
[13] Liu Tiean. Study on the accuracy of flame temperature measurement [J]. Infrared Technology(红外技术),1996,18(6): 42-44 (in Chinese)