本文从三基色测温原理出发,讨论了它在火焰温度场测量应用中受到的限制因素.通过对火焰模型和CCD光谱响应的简化,推导出了便于应用的测温公式.提出了通过系统标定和三种比色温度的相关性校正测量误差的方法.利用设计的一套测量系统,对某200 MW的锅炉的温度场分布进行了测量,并与双色温度计的测量数据进行了比较.结果表明,上述方法简单可靠、测量误差小于5%,可满足系统燃烧诊断和实时测控的目的,工程上有一定的应用前景.

参考文献

[1] Choi M Y,et al.Simultaneous optical measure of soot volume fraction and the temperature in premixed flames[J].Combustion and Flame,1994,99(3):174-196.
[2] Zhou Huaichun,Luo Xinsheng,Xiao Jiaofang,et al.Study on the experiment of the hearth flame temperaturefield[J].Proceeding of CSEE(中国电机工程学报),1995,15(5):295-300(in Chinese).
[3] Xu Kefu.Study on application of digital image processing technology in power station [J].Automation of Electric Power Systems(电力系统自动化),1995,10(4):43-47(in Chinese).
[4] Cheng Xiaofang,Zhou Zhou.Study on temperature-measuring system based on three-color [J].Science in China(Series E)(中国科学(E辑)),1997,(4):342-345(in Chinese).
[5] Wang Shimin,Zhao Yunjun,Wang Feng-lin.Theoretical and experimental investigation on 3-dimensional temperature reconstruction inflame by optical sectioning tomography[J].Journal of Engineering Thermophysics(工程物理学报),2002,(6):234(in Chinese).
[6] Sun Xuan,Xi Xiangdong.Study on furnace flame monitoring and combustion diagnosing based on improved colorimetric temperature-measurement method [J].Power System Engineering (电站系统工程),2001,(11):367-368(in Chinese).