利用光纤光栅作为传感元件,对螺纹钢标准拉伸试验试件的拉伸应变特性进行了分析与测量,采用电阻应变片作为对比测量,并与理论值进行了比较.测量结果FBG2的应变测量灵敏度为15.647 με/kN非常接近理论期望值15.680με/kN,而电阻应变片的应变测量灵敏度仅为14.162 με/kN;同时,利用光纤光栅测量钢筋试件弹性模量,其中FBG2测得弹性模量为2.03×105MPa与标准测量值一致.结果表明,作为测量应变的常用仪器,光纤光栅比电阻应变片具有更强的实用性.

参考文献

[1] Liu Zhiguo, Zhang Yibing, Kai Guiyun, et al. A new method for fiber-grating linear tuning [J]. Acta Optica Sinica (光学学报), 1998, 18(12):1731-1734 (in Chinese).
[2] Weigang Zhang, Xiaoyi Dong, Dejun Geng, et al. Linearly giber grating-type sensing tuning by applying torsion stress [J]. Electron Lett., 2000, 36(20): 1686-1688.
[3] Liao Bangquan, Feng Dejun, Zhao Qida, et al. Theoretical and experimental research on fiber Bragg grating electric current sensor [J]. Acta Optica Sinica (光学学报), 2002, 22(9): 1092-1095 (in Chinese).
[4] Ying Zhang, Dejun Feng, Zhiguo Liu, et al, High-sensitivity pressure sensor using a shielded polymer-coated fiver Bragg grating [J]. IEEE, Photonic Technology Lett., 13(6): 618-619.
[5] Zhang Xingzhou. Optical fiber grating sensor (OFGS) and ‘3S’system [J]. Journal of Transducer Technology,1998, 17(2): 54-60.
[6] Qiao Xueguang, et al. Hxbird FBG/LPED sensor for simultaneous measuring strain and temperture of oil/gas bottomhde [J]. J. of Optoelectronics Laser, 1999, 10(1): 42-45.
[7] Timoshenko S, Gere J. Mechanics of Material [M]. Science Press, 1978.