传统血糖检测需从患者静脉取血,给糖尿病人带来了极大的痛苦和经济负担,利用荧光测试技术进行血糖的无创检测研究.通过对不同葡萄糖浓度的全血、血清和不同浓度的红细胞溶液进行系列荧光光谱实验,结果表明全血在720~730 nm附近有明显荧光特征峰,其中720 nm附近特征峰由血细胞引起、730 nm附近特征峰是由糖份引起,且全血和血清中此位置处峰值强度均随血糖浓度变化而规律性变化.实验结果为进一步进行血糖荧光无创检测打下了基础.
参考文献
[1] | Arnold M A,Burmeister J J,Small G W.Phantom glucose calibration models from simulated noninvasive human near-infrared spectra[J].Anal.Chem.,1998; 70(9):1773. |
[2] | Huang Lan,Ding Haishu,Wang Guangzhi.The preliminary study on noninvasive detection using NIR diffusion reflectance spectrum for monitoring blood glucose[J].Spectroscopy and Spectral Analysis (光谱学与光谱分析),2002,22(3):387-391(in Chinese). |
[3] | Klonoff D C.Non invasive blood glucose monitoring[J].Diabetes Care,1997,20(3):433. |
[4] | Chou C,Lin PK.Non invasive glucose monitoring with optical heterodyne technique[J].Diabetes Technol Ther,2000,2(1):45. |
[5] | Jussi TH.Non-invasive glucose measurement based on selective near infrared absorption; requirements on instrumentation and spectral range[J].Measurement,1998,24:173. |
[6] | Xu Kexin,Cui Houxin,Wang Wenbo.Fundamental study on noninvasive blood glucose measurement[J].Journal of Tianjin University (天津大学学报),2003,36(2):133-137 (in Chinese). |
[7] | Chen Wenliang,Xu Kexin,et al.Techniques of human body non-invasive blood glucose detection[J].Chinese Journal of Scientific Instrument (仪器仪表学报),2003,24(4):258-261 (in Chinese). |
[8] | Zhao Nanming,Zhou Haimeng.Biophysics[J].China Higher Education Press Beijing and Spring-Verlag Heidelberg,2000,275-309. |
[9] | Zhao Zhimin,Chen Yuming,Yu Xiaolei.Characteristic analysis and application of blood fluorescence spectra[J].Spectroscopy and Spectral Analysis (光学与光谱分析),2003,23(5):922-925 (in Chinese). |
[10] | Chen Rong,Chen Yanjiao,Yang Wengqin,et al.Primary study on the blood fluorescence spectrum affected by heNe laser[J].Acta Laser Biology Sinica (激光生物学报),1999,8(1):62-65 (in Chinese). |
[11] | Chen Rong,Xu Shaofeng,et al.Relation between the blood absorption spectrum and phototherapy[J].Chinese Journal of Laser Medicine & Surgery (中国激光医学杂志),1997,6:142-145 (in Chinese). |
[12] | Jiang Yuqiang,Li Changyong,et al.Study on fluorescence spectra of human blood and its components[J].Laser & Optronics Progress (激光与光电子学进展),2001,5:23-26 (in Chinese). |
[13] | Luo Xiaosen,Ni Xiaowu,Gao Shumei,et al.Analysis of fluorescence spectra of blood induced by lights of 530nm and 632.8 nm[J].Journal of Nanjing University of Science and Technology (南京理工大学学报),2003,27(1):73-76 (in Chinese). |
[14] | Gao Shumei,Liu Yaing,Luo Xiansen,et al.Investigation of visible light induced blood fluorescence spectral characteristics[J].Laser Journal (激光杂志),2002,23(5):71-72 (in Chinese). |
[15] | Gao Shumei,Luo Xiaosen,Lan Xiufeng,et al,Analyzing of LED-induced blood fluorescent spectra[J].Chinese Journal of Lasers,2002,B11(4):315-318. |
[16] | Chen Minsen,Chen Wenliang,Du Zhenhui,et al.Study on non-invasive blood glucose detection by near-infrared spectroscopy[J].Modern Instruments (现代仪器),2004,4:38-40 (in Chinese). |
[17] | Zhang Yuping,Yang Shizhi,et al.Detection of weak fluorescence signal in the chlorophyll fluorometer[J].Chinese Journal of Quantum Electronics (量子电子学报),2005,22(2):169-172 (in Chinese). |
[18] | Zong Renhe,Hu Cungang,Liu Jiafeng,et al.Development of application of laser in medicine[J].Chinese Joural of Quanturn Electronics (量子电子学报),2004,21(2):211-215 (in Chinese). |
上一张
下一张
上一张
下一张
计量
- 下载量()
- 访问量()
文章评分
- 您的评分:
-
10%
-
20%
-
30%
-
40%
-
50%