介绍了比色测温理论中的K值来源,通过实验对不同波长组合的K值进行分析,得出它随温度的变化而变化的规律,然后通过插值函数和最小二乘法对K值进行修正以减小比色测温误差,并对两种方法进行比较,得出:用插值函数进行修正在某段会出现较大误差,而利用最小二乘法对K值进行修正则能获得较好效果.

参考文献

[1] Anselmi-Tamburini U,et al.A two-color spatial-scanning pyrometer for the determination of temperature profiles in combustion synthesis reation[J].Rev.Scientific Instruments,1995,66(10):5006-5014.
[2] Jiang Xuedong,Wei Sui,Wu Haibin.The application of image processing in measurement of furnace's flame temperature field[J].Microcomputer Development (微机发展),2002,12(3):34-37 (in Chinese).
[3] An Yuying,Liu Jifang,Li Qinghui.Photoelectron Technique (光电技术).Beijing:Electronics Industry Press,2002.(in Chinese).
[4] Wu Haibin,Chen Jun,Zhang Jie,et al.Selection of two-color wavelengths and minimum bandwidth calculation of filters in colorimetric temperature measurement[J].Chinese Journal Quantum Electronics (量子电子学报),2006,23(4):569-572 (in Chinese).
[5] Guo Daliang,Tang Zhijian.Camera Manual (照相手册)[M].Beijing:Movie China Press,1986.(in Chinese).
[6] Peng Xiaoqi,Zhou Haiye,Song Haiying.The revised three-color temperature measurement method based on CCD and data interpolation[J].Proceedings of the Chinese Society of Electrical Engineering (中国电机工程学报),2004,(8):166-169 (in Chinese).
[7] Lin Chengsen.Data analysis (数值分析)[M].BeiJing:Science Press,2006.(in Chinese).
[8] Hart Danfu,Wu Qingbiao.Numerical Computing Methods (数值计算方法)[M].Zhejiang University Press,2006.6 (in Chinese).