设计了一种加热炉内钢坯表面温度实时检测系统,以DSP为图像处理核心,采集加热炉内两幅临近中心波长的近红外辐射图像,用比色测温算法计算出钢坯表面温度.对比色测温原理、系统的硬件电路、软件流程和试验效果进行了分析.在H型钢加热炉的试验表明,系统能实时检测加热钢坯的表面温度,实时生成加热炉内温度场的伪彩图像并完成工况分析.钢坯表面温度检测的相对误差小于0.5%,满足加热炉温度控制工艺的要求.
A real-time detection system of billet surface temperature measurement in furnace was designed,employing DSP as the image processing center. Two near-infrared radiation images were collected in the furnace, and the billet surface temperature was calculated using the colorimetric thermometry algorithm.The principle of colorimetric thermometry, the system hardware, software and testing effect are analyzed.The testing in the H-beam furnace show that the system can check the whole surface temperature of billet real-time, display the temperature field using pseudo-color image, and analysis the operating conditions of furnace. The relative error of temperature detection accuracy is less than 0.5%, satisfying the demand of the furnace control system.
参考文献
[1] | Wang Wenge.Survey of radiation thermometry technology[J].Journal of Astronautic Metrology and Measurement (宇航计测技术),2005,25(4):20-24,32 (in Chinese). |
[2] | Li Fanghui.TMS320C6000 DSPs Principle and Application (TMS320C6000 系列DSPs 原理与应用)[M].Beijing:Publishing House of Electronics Industry,2003 (in Chinese). |
[3] | Wu Haibin,Chen Jun,Zhang Jie,et al.Selection of two-color wavelengths and minimum bandwidth calculation of filters in colorimetric temperature measurement[J].Chinese Journal of Quantum Electronics (量子电子学报),2006,23(4):569-572 (in Chinese). |
[4] | Jiang Zhongliang,Chen Xiuyun.Temperature Measurement and Control (温度的测量与控制)[M].Beijing:Tsinghua University Press,2005 (in Chinese). |
[5] | Xing Jichuan,et al.Dual waveband chromatic thermometry and its analysis[J].Infrared Technology (红外技术),2002,24(6):73-76 (in Chinese). |
[6] | Altera Corporation.ACEX 1 k programmable logic device family data sheet[DB/OL].2003,http://www.altera.com/literature/ds/acex.pdf. |
[7] | Wu Haibin,Sun Weiya,et al.Research on image preprocessing of strip correction based on CCD imaging[J].Optoelectronic Technology & Information (光电子技术与信息),2005,18(2):85-88 (in Chinese). |
[8] | Wu Haibin,Liu Chunhong.Error modified function of colorimetry of temperature measurement[J].Chinese Journal of Quantum Electronics (量子电子学报),2009,26(1):121-126 (in Chinese). |
- 下载量()
- 访问量()
- 您的评分:
-
10%
-
20%
-
30%
-
40%
-
50%