反渗透装置中最重要的给水预处理方法之一是加入阻垢剂,来防止水中难溶盐形成水垢.RO市场上每年都会推出新的阻垢剂.RO装置的技术人员在使用这些阻垢剂前要对其性能进行实验室评估,研究阻垢剂所可能达到的最大回收率及正确的加药量.文章对阻垢剂的实验室快速评价技术进行了研究.使RO装置以周期性浓缩的全循环模式运行,以逐渐提高RO装置浓水侧的结垢趋势,并测定其结垢速率.选择了新型阻垢剂PTP-2000和传统阻垢剂SHMP,对其阻CaCO3的性能进行了比较研究.结果表明,周期性浓缩的全循环是一种快速、方便、可靠的阻垢剂评价技术.
参考文献
[1] | Darton E G.Membrane chemical research:Centuries apart[J].Desalination,2000:121-131. |
[2] | F.H. Butt;F. Rahman;U. Baduruthamal .Pilot plant evaluation of advanced vs. conventional scale inhibitors for RO desalination[J].Desalination: The International Journal on the Science and Technology of Desalting and Water Purification,1995(3):189-198. |
[3] | Al-Shammiri M;Safar M;Al - Dawas M.Evaluation of two different antiscalants in real operation at Doha Research Plant[J].Desalination,2001:1-16. |
[4] | Pervov A G.Scale formation prognosis and cleaning procedure schedules in reverse osmosis systems operation[J].Desalination,1991:72-118. |
[5] | Pervov A G.A simpliued RO process design based on understanding of fouling mechanisms:Scale formation prognosis and cleaning procedure schedules in reverse osmosis systems operation[J].Desalination,1999:227-247. |
[6] | 时钧;袁权;高从堵.膜技术手册[M].北京:化学工业出版社,2001:279-281. |