大连某热电厂以城市生活污水厂二级出水为原水,经过反渗透深度处理后,出水满足热电厂循环冷却水需求.反渗透系统处理效果明显,对电导率、氨氮和总氮的去除率分别为97.5%,95.7%,94.4%,并几乎将TOC全部去除.系统已运行20个月,稳定可靠,一直为电厂提供循环冷却水,显示出该工艺在实际应用中的可行性,具有推广价值.

Reverse osmosis, as an advanced treatment process, has been applied to treat the secondary effluent from wastewater treatment plant in a thermal power plant in Dalian.The quality of disposal water is above recirculated cooling water standards.The results indicate that the elimination rates of conductivity, ammoniacal nitrogen and total nitrogen are 97.5 %, 95.7% and 94.4 % respectively, and the content of TOC is nearly zero.This system has provided recirculated cooling water for the power plant for about 20 months, which reveals obvious feasibility and promoted value.

参考文献

[1] 杨凤民,邢奕,安永辉,刘健超.热电厂循环冷却水系统水处理技术探讨[J].给水排水,2007(11):184-187.
[2] 宋正昶,王国红.中水用作火电厂循环冷却水的工艺研究[J].工业水处理,2006(10):80-82.
[3] 李盛凯,汪永辉,李培云,郭玉江.A/O接触池处理生活污水并回用[J].中国给水排水,2004(10):91-92.
[4] Abdelhafidh Dhouib;Nadia Hdiji;Ilem Hassaieri;Sami Sayadi .Large scale application of membrane bioreactor technology for the treatment and reuse of an anionic surfactant wastewater[J].Process biochemistry,2005(8):2715-2720.
[5] Petala M;Tsiridis V;Samaras P et al.Wastewater reclamation by advanced treatment of secondary cffluents[J].Desalination,2006,195:109-118.
[6] Frans Knops;Stephan van Hoof;Harry Futselaar .Economic evaluation of a new ultrafiltration membrane for pretreatment of seawater reverse osmosis[J].Desalination: The International Journal on the Science and Technology of Desalting and Water Purification,2007(1/3):300-306.
[7] 靖大为,王春艳,梁全民.反渗透系统给水电导率与pH的系统影响[J].工业水处理,2006(03):62-64.
上一张 下一张
上一张 下一张
计量
  • 下载量()
  • 访问量()
文章评分
  • 您的评分:
  • 1
    0%
  • 2
    0%
  • 3
    0%
  • 4
    0%
  • 5
    0%