采用自制聚丙烯中空纤维膜接触器,以海水作为吸收剂,对模拟烟气中CO2进行吸收试验研究,主要考察烟气流量、CO2浓度、海水流量、海水pH值及膜填充率对CO2脱除率及膜接触器传质性能的影响.研究结果表明:(1)提高烟气流量或CO2浓度能提高膜接触器对CO2的处理量,导致脱碳率下降;(2)提高海水流量能明显提高脱碳率和传质速率;(3)提高海水pH可增大海水对CO2的吸收能力,直接决定了海水对CO2的吸收机制;(4)增大膜接触器填充率所对应的脱碳率并非最高,有效气液接触面积是影响脱碳率和过程传质的重要因素.
参考文献
[1] | Zhang Qi;Cussler E L .Micropomus hollow fibers for gas absorption I mass transfer in the liquid[J].Journal of Membrane Science,1985,23(03):321-332. |
[2] | Zhang Qi;Cussler E L .Microporous hollow fibers for gas absorption Ⅱ mass transfer across the membrane[J].Journal of Membrane Science,1985,23(03):333-345. |
[3] | Atchariyawut S;Jiraratananon R;Wang R .Separation of CO2 from CH4 by using gas-liquid membrane contacting process[J].Journal of Membrane Science,2007(1/2):163-172. |
[4] | 陆建刚,马骏,王连军.膜接触器分离混合气中二氧化碳[J].膜科学与技术,2005(05):15-20. |
[5] | 蔡培,王树立,赵书华.脱碳醇胺溶液性能的研究[J].膜科学与技术,2009(06):71-74. |
[6] | Young-Seok Kim;Seung-Man Yang .Absorption of carbon dioxide through hollow fiber membranes using various aqueous absorbents[J].Separation and Purification Technology,2000(1/2):101-109. |
[7] | 孙海敏,张国亮,刘飞妮,杨阿三,孟琴.对中空纤维膜接触器空间结构的分析与探讨[J].膜科学与技术,2008(04):53-58. |
[8] | Dindore VY;Brilman DWF;Versteeg GE .Modelling of cross-flow membrane contactors: Mass transfer with chemical reactions[J].Journal of Membrane Science,2005(1/2):275-289. |
[9] | 陆建刚,王连军,刘晓东,孙秀云,李健生.膜基复合溶液吸收CO2过程模拟[J].化工学报,2005(08):1439-1444. |
[10] | Aldo Bottino;Gustavo Capannelli;Antonio Comite .CO2 removal from a gas stream by membrane contactor[J].Separation and Purification Technology,2008(1):85-90. |
[11] | Meral Nugent .Adding lime to seawater may cut CO2levels back to pre-industrialized levels[J].Chemical Engineering World,43(09):101-102. |
[12] | 孙承贵 .中空纤维致密膜基吸收脱除CO<,2>研究[D].中国科学院大连化学物理研究所,2005. |
[13] | 国家环境保护总局<水和废水监测分析方法>编委会.水和废水监测分析方法[M].北京:中国环境科学出版社,2002:120-125. |
上一张
下一张
上一张
下一张
计量
- 下载量()
- 访问量()
文章评分
- 您的评分:
-
10%
-
20%
-
30%
-
40%
-
50%