以海水作为吸收剂,采用模拟烟气,对气-液膜接触器进行传质性能评价试验,考察其工艺结构参数、气液介质流动速率及方式、气液压差、烟气SO2浓度等因素对传质系数、脱硫率及膜效用的影响.试验表明,在气相压力较低情况下,气液流速、气液压差对总气相传质系数影响明显,而烟气SO2浓度的影响可忽略不计.适当提高膜接触器的填充密度,增加膜吸收级数,采用错流模式的气液流动方式,均可改善烟气流场分布,增大有效传质面积,提高膜效用,与传统吸收塔相比,新型膜气体吸收装置的气液两相独立控制,可灵活应对烟气浓度变化对脱硫稳定性的影响,同时具有低气阻、耐污染、规模可线性放大等优点,工业化应用前景广阔.
参考文献
[1] | Filtration + Separation Group .Achieving Flue Gas Desulphurization with Membrane Gas Absorption[J].Filtration + Separation,2003(10):26-28. |
[2] | S. Mohebi;S.M. Mousavi;S. Kiani .Modeling and simulation of sour gas membrane-absorption system: Influence of operational parameters on species removal[J].Journal of natural gas science and engineering,2009(6):195-204. |
[3] | S.N. Ashrafizadeh;Z. Khorasani .Ammonia removal from aqueous solutions using hollow-fiber membrane contactors[J].Chemical engineering journal,2010(1):242-249. |
[4] | Dindore VY;Brilman DWF;Versteeg GF .Modelling of cross-flow membrane contactors: physical mass transfer processes[J].Journal of Membrane Science,2005(1/2):209-222. |
[5] | Iversen SB.;Damjohansen K.;Jonsson G.;Bhatia VK. .CHARACTERIZATION OF MICROPOROUS MEMBRANES FOR USE IN MEMBRANE CONTACTORS[J].Journal of Membrane Science,1997(1/2):205-217. |
[6] | Kreulen H;Smolders C A;Verstee G F .Micro-porous hollow fiber membrane modules as gas-liquid contactors Part2.Mass transfer with chemical reaction[J].Journal of Membrane Science,1993,78(03):217-238. |
[7] | Matsuda N.;Yamamoto K.;Iwasaki H.;Sakai K. .Effects of hollow fiber packing fraction on blood flow pattern and gas transfer rate of an intravascular oxygenator (IVOX)[J].Journal of Membrane Science,2000(1/2):231-241. |