介绍了所研制的漆包线绝缘耐脉冲电压强度测试装置的工作原理和性能指标.根据脉冲宽度调制(PWM)电压波形的特性,确定了PwM模拟发生器的脉冲电压参数.该装置输出的脉冲方波幅值1.6~-1.6kV连续可调,频率20kHz,方波宽度20.15μs,方波电压上升时间空载16.2ns,满载25ns,可同时测量五个绞线对试样,还具有自动保护、自动记时功能.测试结果表明:测试装置的主要性能达到国际同类测试仪的先进指标,可以满足国内变频电机漆包线质量评定的需要.
参考文献
[1] | Cerutti B;Guastavino F;Castagnini A;Gemme C.Characterisation of insulated conductors for high frequency application[A].,1999:573-576. |
[2] | Weijun Tin .Dielectric properties of an improved magnet wire for inverter-fed motors[J].IEEE Electron Device Letters,1977,13(04):17-23. |
[3] | 马寒冰,施利毅,沈嘉年,李锦梁,刘守忠.新型耐变频纳米绝缘漆的研制[J].绝缘材料,2003(01):30-32,35. |
[4] | David A Metzer;Johm E Hake .The effects of mechanical deformation and wure size on the ozone erosiom resistance of inverter-duty magnet wire[R].Report of Rea Magnet Wire Co., Inc,1999. |
[5] | Kaufhold M.;Borner G. .Failure mechanism of the interturn insulation of low voltage electric machines fed by pulse-controlled inverters[J].IEEE Electrical Insulation Magazine,1996(5):9-16. |
[6] | Weijun Yin .Failure mechanism of winding insulations in inverter-fed motors[J].IEEE Electrical Insulation Magazine,1997(6):18-23. |