提出超临界区制冷剂热力性质的隐式拟合模型,给出了超临界区制冷剂热力性质的隐式拟合、显式计算方法.该方法能够保证超临界区热力性质计算的可逆性、高速性和绝对稳定性.以REFPROP 7的计算结果作为数据源,以CO2为例对该模型作了验证.对CO2超临界区热力性质在温度为304.15~393.15 K,压力在7.3773~12.0 MPa的数据范围内作了隐式拟合,给出了各个热力性质对应的显式快速计算公式,其计算速度比REFPROP 7程序的计算速度平均提高了2个数量级,并且平均误差在1.8%以内.
参考文献
[1] | Chan CY;Haselden GG .Computer-based refrigerant thermodynamic properties.Part 1.Basic equations[J].International Journal of Refrigeration-Revue Internationale du Froid,1981,4(01):7-12. |
[2] | Eric W Lemmon;Mark O McLinden;Marcia L Huber.NIST REFPROP 7[M].USA:National Institute of Standards and Technology,2003 |
[3] | Guoliang Ding;Zhigang Wu;Jian Liu;Takefumi Inagaki;Kaijian Wang;Masaharu Fukaya .An implicit curve-fitting method for fast calculation of thermal properties of pure and mixed refrigerants[J].International Journal of Refrigeration,2005(6):921-932. |
[4] | Guo Liang Ding;Zhigang Wu;Kaijian Wang;Masaharu Fukaya .Extension of the applicable range of the implicit curve-fitting method for refrigerant thermodynamic properties to critical pressure[J].International Journal of Refrigeration,2007(3):418-432. |
[5] | 吴志刚,丁国良.制冷剂热力性质的快速计算Ⅰ.计算方法[J].上海交通大学学报,2006(02):297-300. |