本文建立了小型平板CPL蒸发器毛细多孔芯内汽液两相流动与传热的模型以及金属外壁和工质区的导热模型,并进行耦合求解.分析了金属侧壁效应对蒸发器性能的影响,提出小型平板CPL存在着侧壁效应传热极限.数值结果表明,工质蒸发发生在多孔芯加热表面附近,蒸发器采用单一金属外壁时由于侧壁效应导致系统传热极限低,而上壁采用导热系数大,侧壁及下壁采用导热系数小的新型结构能够明显的提高系统的传热能力,同时使加热表面的温度维持在较低的水平.

参考文献

[1] Pin-Chih Chen;Wei-Keng Lin .The application of capillary pumped loop for cooling of electronic components[J].Applied thermal engineering: Design, processes, equipment, economics,2001(17):1739-1754.
[2] Figus C.;Bories S.;Prat M.;Le Bray Y. .Heat and mass transfer with phase change in a porous structure partially heated: Continuum model and pore network simulations[J].International Journal of Heat and Mass Transfer,1999(14):2557-2569.
[3] 韩延民,刘伟,黄晓明.CPL蒸发器多孔芯内传热传质的非稳态数值模拟[J].宇航学报,2003(04):397-403.
[4] 陶文铨.数值传热学[M].西安:西安交通大学出版社,2003