为了在亚临界到临界点这个大范围内保证制冷剂物性计算的快速、稳定、可逆,提出将整个数据区间划分成若干个子区间分别进行隐式拟合,并且保证相邻子区间连接点处的连续与光滑,以及通过求分析解从隐式方程中得到显式物性计算式的方法.以美国国家标准局开发的程序REFPROP6.01的计算结果作为数据源,以R410A为例对该方法做了验证.得出快速物性计算公式的应用范围为饱和温度-60℃至临界温度,与NIST REFPROP 6.01的计算结果进行比较表明,计算速度快1500倍,平均相对偏差小于0.01%.
参考文献
[1] | Jian Liu;WenJian Wei;GouLiang Ding;Chunlu Zhang;Masaharu Fukaya;Kaijian Wang;Takefumi Inagaki .A general steady state mathematical model for fin-and-tube heat exchanger based on graph theory[J].International Journal of Refrigeration,2004(8):965-973. |
[2] | NIST REFPROP 6.01[M].National Institute of Standard,USA |
[3] | Cleland AC .Polynomial Curve-Fits for Refrigerant Thermodynamic Properties:Extension to Include R134a[J].International Journal of Refrigeration,1994,17(04):245-249. |
[4] | Charters WWS;Sadafi HA .Saturation Property Equation for R22[J].International Journal of Refrigeration,1987,10(02):103-104. |
[5] | Martin-Dominguez IR;McDonald TW .Correlations for some Saturated Thermodynamic and Transport Properties of Refrigerant R-22[J].ASHRAE Transactions,1993,99(01):344-348. |
[6] | 张春路;丁国良;李灏 .制冷剂饱和热力性质的隐式拟合方法[J].工程热物理学报,1999,20(06):673-676. |
[7] | 张春路,丁国良,李灏.制冷剂过热气体热力性质的隐式拟合方法[J].工程热物理学报,2000(05):533-536. |
[8] | Guoliang Ding;Zhigang Wu;Jian Liu;Takefumi Inagaki;Kaijian Wang;Masaharu Fukaya .An implicit curve-fitting method for fast calculation of thermal properties of pure and mixed refrigerants[J].International Journal of Refrigeration,2005(6):921-932. |