通过10个故障实例,从设备、阳极、镀液成分、电镀温度等4个方面分析了酸性硫酸盐镀铜生产现场出现“电镀电流下降、电压升高”故障的原因,并给出了对应的处理方法,指出了预防类似故障的15个技术要点。
The causes of decreasing current with increasing voltage in acid sulfate copper plating were analyzed from devices, anode, bath composition, and plating temperature in terms of 10 fault instances. The corresponding treatment measures were provided. Fifteen technical points to prevent faults were given.
参考文献
[1] | 霍大勇.电镀生产线中直流母排上的电气问题[J].电镀与涂饰,2011(09):21-23. |
[2] | 刘仁志.电镀实用技术问答[M].北京:机械工业出版社,2011 |
[3] | 袁诗璞,毛茂财,汪小英.光亮酸铜液中Cl-含量对镀层外观的影响[J].电镀与涂饰,2007(10):11-14. |
[4] | 张炳乾;何长林.电镀液故障处理[M].北京:国防工业出版社,2006 |
上一张