A novel combination microelectrode was constructed based on an iridium pH microelectrode and an Ag/AgCl microelectrode, and was applied to simultaneously monitor the steel potential, pH and chloride ion concentration in a crevice simulating disbonding of pipeline coatings with cathodic protection ( CP) applied or removed. The sensing characteristics and sensitivity of the microelectrode are described as well as the calibration procedures. A simulated crevice was formed between a pipeline steel surface and a polymethylmethacrylate plate. The results showed that in CP conditions, the evident potential gradient resulting from the IR potential drop was concentrated at the crevice opening. A protective local environment induced by CP under disbonded coatings was characterised by an increase in pH and removal of Cl-. After CP is removed, the protective effects can persist for a period of time, depending on the diffusion of soluble species.