铁及其合金具有优良的力学性能、可降解性及生物相容性等,是一种潜在的可降解支架材料.综述了可降解铁基支架材料的最新研究进展,详细介绍了纯铁及其合金支架材料的力学性能、降解性能、生物相容性和动物实验,分析了铁基支架材料的发展趋势,并展望了其未来研究方向.
参考文献
[1] | Sigwart U;Puel J;Mirkovitch V et al.Intravascular stents to prevent occlusion and re-stenosis after transluminal angioplasty[J].New England Journal of Medicine,1987,316(12):701. |
[2] | 李涛,吕志前.生物可降解支架研究进展[J].解剖科学进展,2008(04):436-440. |
[3] | Hermawan H;Dube D;Mantovani D .Developments in metallic biodegradable stents.[J].Acta biomaterialia,2010(5):1693-1697. |
[4] | Nishio,S.;Kosuga,K.;Igaki,K.;Okada,M.;Kyo,E.;Tsuji,T.;Takeuchi,E.;Inuzuka,Y.;Takeda,S.;Hata,T.;Takeuchi,Y.;Kawada,Y.;Harita,T.;Seki,J.;Akamatsu,S.;Hasegawa,S.;Bruining,N.;Brugaletta,S.;DeWinter,S.;Muramatsu,T.;Onuma,Y.;Serruys,P.W.;Ikeguchi,S. .Long-term (>10 Years) clinical outcomes of first-in-human biodegradable poly-l-lactic acid coronary stents: Igaki-Tamai stents[J].Circulation: An Official Journal of the American Heart Association,2012(19):2343-2352. |
[5] | Witte F .The history of biodegradable magnesium implants: a review.[J].Acta biomaterialia,2010(5):1680-1692. |
[6] | Rab S T;King S B;Roubin G S et al.Coronary aneursms after stent placement:Asuggestion of altered vessel wall healing in the presence of anti-inflammatory agents[J].Journal of the America College of Cardiology,2001,18(06):1524. |
[7] | Guangling Song;Shizhe Song .A Possible Biodegradable Magnesium Implant Material[J].Advanced Engineering Materials,2007(4):298-302. |
[8] | Mani G;Feldman MD;Patel D;Agrawal CM .Coronary stents: A materials perspective[J].Biomaterials,2007(9):1689-1710. |
[9] | Jian Chen;Junhua Dong;Jianqiu Wang;Enhou Han;Wei Ke .Effect Of Magnesium Hydride On The Corrosion Behavior Of An Az91 Magnesium Alloy In Sodium Chloride Solution[J].Corrosion Science: The Journal on Environmental Degradation of Materials and its Control,2008(12):3610-3614. |
[10] | Yeoheung Yun;Zhongyun Dong;Namheon Lee;Yijun Liu;Dingchuan Xue;Xuefei Guo;Julia Kuhlmann;Amos Doepke;H. Brian Halsall;William Heineman;Surya Sundaramurthy;Mark J. Schulz;Zhangzhang Yin;Vesselin Shanov;Douglas Hurd;Peter Nagy .Revolutionizing biodegradable metals[J].Materials Today,2009(10):22-32. |
[11] | Purnama A;Hermawan H;Couet J;Mantovani D .Assessing the biocompatibility of degradable metallic materials: state-of-the-art and focus on the potential of genetic regulation.[J].Acta biomaterialia,2010(5):1800-1807. |
[12] | Peuster M;Beerbaum P;Bach F W et al.Are resorbable implants about to become a reality[J].Cardiology in the young,2006,16(02):107. |
[13] | 朱生发,徐莉,李贵才,石志峰,孙鸿,黄楠.可降解纯铁薄膜的制备和血液相容性[J].材料研究学报,2008(05):495-499. |
[14] | M Peuster;P Wohlsein;M Brugmann .A novel approach to temporary stenting: degradable cardiovascular stents produced from corrodible metal - results 6-18 months after implantation into New Zealand white rabbits[J].Heart,2001(5):563-569. |
[15] | Mueller PP;May T;Perz A;Hauser H;Peuster M .Control of smooth muscle cell proliferation by ferrous iron.[J].Biomaterials,2006(10):2193-2200. |
[16] | Shengfa Zhu;Nan Huang;Li Xu;Yu Zhang;Hengquan Liu;Hong Sun;Yongxiang Leng .Biocompatibility of pure iron: In vitro assessment of degradation kinetics andcytotoxicity on endothelial cells[J].Materials science & engineering, C. Biomimetic and supramolecular systems,2009(5):1589-1592. |
[17] | Peuster M;Hesse C;Schloo T;Fink C;Beerbaum P;von Schnakenburg C .Long-term biocompatibility of a corrodible peripheral iron stent in the porcine descending aorta.[J].Biomaterials,2006(28):4955-4962. |
[18] | Waksman R;Pakala R;Baffour R;Seabron R;Hellinga D;Tio FO .Short-term effects of biocorrodible iron stents in porcine coronary arteries.[J].Journal of interventional cardiology,2008(1):15-20. |
[19] | Schinhammer M;Hanzi AC;Loffler JF;Uggowitzer PJ .Design strategy for biodegradable Fe-based alloys for medical applications.[J].Acta biomaterialia,2010(5):1705-1713. |
[20] | Afshari V;Dehghanian C .Effects of grain size on the electrochemical corrosion behavior of electrodeposited nanocrystalline Fe coatings in alkaline solution[J].Corrosion Science,2009,51(08):1844. |
[21] | Biocorrosion properties and blood and cell compatibility of pure iron as a biodegradable biomaterial[J].Journal of Materials Science. Materials in Medicine,2010(7):2151-2163. |
[22] | Nie, F.L.;Zheng, Y.F.;Wei, S.C.;Hu, C.;Yang, G. .In vitro corrosion, cytotoxicity and hemocompatibility of bulk nanocrystalline pure iron[J].Biomedical materials,2010(6):065015-1-065015-10. |
[23] | Moravej M;Prima F;Fiset M;Mantovani D .Electroformed iron as new biomaterial for degradable stents: development process and structure-properties relationship.[J].Acta biomaterialia,2010(5):1726-1735. |
[24] | Moravej M;Purnama A;Fiset M;Couet J;Mantovani D .Electroformed pure iron as a new biomaterial for degradable stents: in vitro degradation and preliminary cell viability studies.[J].Acta biomaterialia,2010(5):1843-1851. |
[25] | Levesque J;Hermawan H;Dube D;Mantovani D .Design of a pseudo-physiological test bench specific to the development of biodegradable metallic biomaterials.[J].Acta biomaterialia,2008(2):284-295. |
[26] | Maryam Moravej;Sofiene Amira;Frederic Prima .Effect of electrodeposition current density on the microstructure and the degradation of electroformed iron for degradable stents[J].Materials Science & Engineering, B. Solid-State Materials for Advanced Technology,2011(20):1812-1822. |
[27] | Hermawan H;Dubé D;Mantovani D .Development of degradable Fe-35Mn alloy for biomedical application[J].Adv Mater Res,2007,15:107. |
[28] | Hermawan H;Alamdari H;Mantovani D et al.Iron-manganese:New class of metallic degradable biomaterials prepared by powder metallurgy[J].Powder Metallurgy,2008,51(i):38. |
[29] | Hermawan,H.;Dubé,D.;Mantovani,D. .Degradable metallic biomaterials: Design and development of Fe-Mn alloys for stents[J].Journal of biomedical materials research, Part A,2010(1):1-11. |
[30] | Hermawan H;Purnama A;Dube D;Couet J;Mantovani D .Fe-Mn alloys for metallic biodegradable stents: degradation and cell viability studies.[J].Acta biomaterialia,2010(5):1852-1860. |
[31] | Liu B;Zheng YF .Effects of alloying elements (Mn, Co, Al, W, Sn, B, C and S) on biodegradability and in vitro biocompatibility of pure iron.[J].Acta biomaterialia,2011(3):1407-1420. |
[32] | Bernd Wegener;Birte Sievers;Sandra Utzschneider .Microstructure, cytotoxicity and corrosion of powder-metallurgical iron alloys for biodegradable bone replacement materials[J].Materials Science & Engineering, B. Solid-State Materials for Advanced Technology,2011(20):1789-1796. |
[33] | 徐文利,陆喜,谭丽丽,杨柯.新型生物可降解Fe-30Mn-1C合金的性能研究[J].金属学报,2011(10):1342-1347. |
[34] | B. Liu;Y.F. Zheng;Liquan Ruan .In vitro investigation of Fe30Mn6Si shape memory alloy as potential biodegradable metallic material[J].Materials Letters,2011(3):540-543. |
[35] | Gu X N;Zheng Y F .A review on magnesium alloys as biodegradable materials[J].Front Mater Sci China,2010,4:1115. |
[36] | Hermawana H;Moravej M et al.Degradation behaviour of metallic biomaterials for degradable stents[J].Adv Mater Res,2007,15-17:113. |
上一张
下一张
上一张
下一张
计量
- 下载量()
- 访问量()
文章评分
- 您的评分:
-
10%
-
20%
-
30%
-
40%
-
50%