欢迎登录材料期刊网

材料期刊网

高级检索

为了考察不同涂层工艺对冠脉支架涂层的影响,分别采用手动浸涂和自动超声喷涂法在316L不锈钢冠脉支架基体表面制备含雷帕霉素的聚碳酸亚乙酯(PEC)涂层.首先对PEC进行了凝胶渗透色谱(GPC)、差示扫描量热(DSC)以及拉伸实验测试,初步证明其物理化学性质适合作支架可降解涂层材料.然后用扫描电子显微镜( SEM)、原子力显微镜(AFM)、接触角测定仪、球囊扩张法等对涂层表面的形貌、亲水性以及涂层和支架基体的结合力进行分析,并在PBS(pH=7.4)模拟体液中测试上述两种工艺方法制备的药物洗脱支架体外药物释放动力学曲线.结果表明,上述两种方法制备的药物涂层在微观结构、亲水性以及与支架的结合力方面存在一定差异,药物释放速率和释放趋势也有所不同,超声喷涂法制备的药物洗脱支架释放速率和释放趋势较稳定.

参考文献

[1] Douglas J S .Role of adjunct pharmacologic therapy in the era of drug-eluting stents[J].Atherosclerosis Supplements,2005,6(04):47.
[2] Balram Bhargava;Ganesan Karthikeyan;Alexandre S Abizaid;Roxana Mehran .New approaches to preventing restenosis[J].BMJ: British medical journal,2003(7409):274-279.
[3] Byrne RA;Sarafoff N;Kastrati A .Drug-eluting stents in percutaneous coronary intervention: a benefit-risk assessment.[J].Drug safety,2009(9):749-770.
[4] Finn A V;Nakazawa G;Joner M et al.Vascular responses to drug eluting stents:Importance of delayed healing[J].Arteriosclerosis,Thrombosis,and Vascular Biology,2007,27(07):1500.
[5] Byrne R A;Joner M;Kastrati A .Polymer coatings and delayed arterial healing following drug-eluting stent implantation[J].Minerva Cardioangiologica,2009,57(05):567.
[6] Wessely R .New drug-eluting stent concepts.[J].Nature reviews. Cardiology,2010(4):194-203.
[7] Han Yaling;Jing Quanmin;Li Yi et al.Sustained clinical safety and efficacy of a biodegradable-polymer coated sirolimus-eluting stent in "real-world” practice:Three-year outcomes of the CREATE (muhi-center registry of EXCEL biodegradable polymer drug eluting stents) study[J].Catheterization and Cardiovascular Interventions,2012,79(02):211.
[8] 张春怀,许鑫华,朱天兵,闫学良,姚康德.冠状动脉支架材料的研究进展[J].材料导报,2007(02):120-124.
[9] 刘洪泽,齐民,吴云峰,魏志勇,黄莹莹,张世轩.制备方法对高分子载药涂层结构和体外释放动力学的影响[J].功能材料,2007(10):1727-1730.
[10] Dadsetan M.;Christenson EM.;Unger F.;Ausborn M.;Kissel T.;Hiltner A. Anderson JM. .In vivo biocompatibility and biodegradation of poly(ethylene carbonate)[J].Journal of Controlled Release: Official Journal of the Controlled Release Society,2003(3):259-270.
[11] Stoll G H;Nimmerfall F;Acemoglu M et al.Poly(ethy lene carbonate)s,part Ⅱ:Degradation mechanisms and pa renteral delivery of bioactive agents[J].Journal of Controlled Release,2001,76(03):209.
[12] Acemoglu M .Chemistry of polymer biodegradation and implications on parenteral drug delivery.[J].International Journal of Pharmaceutics,2004(1/2):133-139.
[13] Stettler C;Wandel S;Allemann S;Kastrati A;Morice MC;Schomig A;Pfisterer ME;Stone GW;Leon MB;de-Lezo JS;Goy JJ;Park SJ;Sabate M;Suttorp MJ;Kelbaek H;Spaulding C;Menichelli M;Vermeersch P;Dirksen MT;Cervinka P;Petronio AS;Nordmann AJ .Outcomes associated with drug-eluting and bare-metal stents: a collaborative network meta-analysis.[J].The Lancet,2007(9591):937-948.
[14] 王献红;路宏伟;赵晓江 et al.The load rare earth ternary catalyst and the preparing method that are used for thecombined polymerization of carbon dioxide and epoxide(用于二氧化碳和环氧化物共聚合的负载稀土三元催化剂及制法)[P].CN,200810051413,2008.
[15] Acemoglu M;Nimmerfall F;Bantle S et al.Poly(ethylene carbonate) s:Part Ⅰ.Synthesis and structural effects on biodegradation[J].Journal of Controlled Release,1997,49(02):263.
[16] Prince Antony;Judit E.Puskas;Marianna Kontopoulou .Investigation of the Rheological and Mechanical Properties of a Polystyrene-Polyisobutylene-Polystyrene Triblock Copolymer and Its Blends with Polystyrene[J].Polymer engineering and science,2003(1):243-253.
[17] 刘强,程晓农,徐红星,费黄霞.316L不锈钢和NiTi合金微磁场表面粗糙度对血液相容性的影响[J].材料研究学报,2009(03):323-326.
[18] 王伟强,梁栋科,杨大智,齐民.冠脉支架系统瞬时膨胀过程的有限元分析及其优化设计[J].中国生物医学工程学报,2005(03):313-318,329.
[19] 谭丽丽,薛松,杨柯,张炳春,刘冬雪,梁勇.冠脉支架表面载药涂层的制备和性能[J].材料研究学报,2004(04):380-384.
上一张 下一张
上一张 下一张
计量
  • 下载量()
  • 访问量()
文章评分
  • 您的评分:
  • 1
    0%
  • 2
    0%
  • 3
    0%
  • 4
    0%
  • 5
    0%