本文对不同工况下闭式振荡热管内工质流动状态及其传热性能进行了实验研究,分析了流动状态、加热功率及倾斜角之间的相互影响关系.结果表明,随着加热功率的升高及倾斜角在 0°~90°范围内的增大,管内工质循环流动趋势增强,热管的热阻减小,工质的充液量限制了高功率时热管性能的进一步提高;冷热端温差随加热功率的升高呈上升-下降-再上升的变化规律,90°和 70°倾角下冷热端温差的最低值所对应的加热功率分别为100 W及125W.
参考文献
[1] | Sameer Khandekar;Anant Prasad Gautam;Pavan K. Sharma .Multiple quasi-steady states in a closed loop pulsating heat pipe[J].International Journal of Thermal Sciences,2009(3):535-546. |
[2] | Shi LIU,Jingtao LI,Xiangyuan DONG,Huanzhuo CHEN.Experimental Study of Flow Patterns and Improved Configurations for Pulsating Heat Pipes[J].热科学学报(英文版),2007(01):56-62. |
[3] | B. Y. Tong;T. N. Wong;K. T. Ooi .Closed-loop pulsating heat pipe[J].Applied thermal engineering: Design, processes, equipment, economics,2001(18):1845-1862. |
[4] | J.L. Xu;Y.X. Li;T.N. Wong .High speed flow visualization of a closed loop pulsating heat pipe[J].International Journal of Heat and Mass Transfer,2005(16):3338-3351. |